Three quantitative ultrasound parameters reflect bone structure.

Abstract

We investigated whether quantitative ultrasound (QUS) parameters are associated with bone structure. In an in vitro study on 20 cubes of trabecular bone, we measured broadband ultrasound attenuation (BUA) and two newly defined parameters--ultrasound velocity through bone (UVB) and ultrasound attenuation in bone (UAB). Bone mineral density (BMD) was measured by dual X-ray absorptiometry (DXA) and bone structure was assessed by microcomputed tomography (microCT) with approximately 80 microns spatial resolution. We found all three QUS parameters to be significantly associated with bone structure independently of BMD. UVB was largely influenced by trabecular separation, UAB by connectivity, and BUA by a combination of both. For a one standard deviation (SD) increase in UVB, a decrease in trabecular separation of 1.2 SD was required compared with a 1.4 SD increase in BMD for the same effect. A 1.0 SD increase in UAB required a reduction in connectivity of 1.4 SD. Multivariate models of QUS versus BMD combined with bone structure parameters showed squared correlation coefficients of r2 = 0.70-0.85 for UVB, r2 = 0.27-0.56 for UAB, and r2 = 0.30-0.68 for BUA compared with r2 = 0.18-0.58 for UVB, r2 < 0.26 for UAB and r2 < 0.13 for BUA for models including BMD alone. QUS thus reflects bone structure, and a combined analysis of QUS and BMD will allow for a more comprehensive assessment of skeletal status than either method alone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C C Glüer, C Y Wu, M Jergas, S A Goldstein, H K Genant. 1994. Three quantitative ultrasound parameters reflect bone structure.. https://doi.org/10.1007/bf00310168

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗