PubMed Health⌕ Search

PubMed · 7964378

Doppler-shift compensation by the mustached bat: quantitative data.

Abstract

Quantitative data for Doppler-shift compensation by Pteronotus parnellii parnellii were obtained with a device which propelled the bats at constant velocities over a distance of 12 m. The bats compensated for Doppler shifts at all velocities tested (0.1-5.0 ms-1). The main findings were (1) that compensation was usually accomplished by a progressive lowering of the approximately 61 kHz second harmonic constant-frequency component of emitted sounds in small frequency steps (93 +/- 72 Hz); (2) that the time needed to reach a steady compensation level averaged 514 +/- 230 ms and the number of pulses required to reach full compensation averaged 10.78 +/- 5.16; (3) that the animals compensated to hold the echo (reference) frequency at a value that was slightly higher than the resting frequency and slightly lower than the cochlear resonance frequency; (4) that reference frequency varied as a function of velocity, the higher the velocity of the animal, the higher was the reference frequency (slope 55 Hz m-1s-2); and (5) that the mean reference frequency was always an undercompensation. The average amount of undercompensation was 15.8%. There was a significant difference (P < or = 0.005) in Doppler-shift compensation data collected at velocities that differed by 0.1 ms-1. A velocity difference of 0.1 ms-1 corresponds to a Doppler-shift difference of about 35 Hz in the approximately 61 kHz signals reaching the ear.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A W Keating, O W Henson, M M Henson, W C Lancaster, D H Xie. 1994. Doppler-shift compensation by the mustached bat: quantitative data.. https://doi.org/10.1242/jeb.188.1.115

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of gamma irradiation on mechanical properties of defatted trabecular bone allografts assessed by speed-of-sound measurement.

New sterilization methods for human bone allografts may lead to alterations in bone mechanical properties, which strongly influence short- and medium-term outcomes. In many sterilization procedures, bone allografts are subjected to gamma irradiation, usually with 25 KGy, after treatment and packaging. We used speed-of-sound (SOS) measurements to evaluate the effects of gamma irradiation on bone. All bone specimens were subjected to the same microbial inactivation procedure. They were then separated into three groups, of which one was treated and not irradiated and two were exposed to 10 and 25 KGy of gamma radiation, respectively. SOS was measured using high- and low-frequency ultrasound beams in each orthogonal direction. SOS and Young modulus were altered significantly in the three groups, compared to native untreated bone. Exposure to 10 or 25 KGy had no noticeable effect on the study variables. The impact of irradiation was small compared to the effects of physical or chemical defatting. Reducing the radiation dose used in everyday practice failed to improve graft mechanical properties in this study.

Acoustics↗

Objective and subjective evaluation of the acoustic comfort in classrooms.

The acoustic comfort of classrooms in a Brazilian public school has been evaluated through interviews with 62 teachers and 464 pupils, measurements of background noise, reverberation time, and sound insulation. Acoustic measurements have revealed the poor acoustic quality of the classrooms. Results have shown that teachers and pupils consider the noise generated and the voice of the teacher in neighboring classrooms as the main sources of annoyance inside the classroom. Acoustic simulations resulted in the suggestion of placement of perforated plywood on the ceiling, for reduction in reverberation time and increase in the acoustic comfort of the classrooms.

Acoustics↗

Analysis of effective radiating area, power, intensity, and field characteristics of ultrasound transducers.

OBJECTIVE: To characterize the ultrasound fields produced by a cohort of transducers from a single manufacturer via hydrophone and Schlieren technology. DESIGN: Descriptive study. SETTING: Measurement laboratory. PARTICIPANTS: Seven same-model ultrasound transducers from a single manufacturer. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Effective radiating area (ERA), total power, spatial average intensity (SAI), beam nonuniformity ratio (BNR), and Schlieren beam widths at 1.0 and 3.3 MHz. RESULTS: Values for ERA (1.0 MHz range, 3.62-4.38 cm(2); 3.3 MHz range, 3.74-4.76 cm(2)), total power (1.0 MHz range, 5.0-5.6 W; 3.3 MHz range, 4.7-5.7 W), SAI (1.0 MHz range, 1.2-1.4 W/cm(2); 3.3 MHz range, 1.0-1.5 W/cm(2)), and BNR (1.0 MHz range, 2.79-5.85; 3.3 MHz range, 2.51-4.56) fell within manufacturer's specifications and U.S. Food and Drug Administration (FDA) regulations. Schlieren analysis showed significantly larger beam widths at 3.3 MHz compared with 1.0 MHz and a large degree of variability in the ultrasound fields generated by the different transducers. There were no significant correlations between beam widths and ERA values. CONCLUSIONS: ERA and total power values in a test cohort exist within a range that met FDA regulations. Individual variability in ERA and total power resulted in 50% variability in SAI. This variability may help explain previous reports of heating differences between transducers.

Acoustics↗