[Simple tests for small intestinal function].

Abstract

Simple tests of small intestinal function not only allow to verify and quantitate malabsorption syndromes, but also permit to make first differential diagnostic decisions which in turn allow to employ more invasive or elaborate techniques on a more rational and restricted base. Essential diagnostic procedures comprise the analysis of fecal wet weight, fecal fat excretion, occasionally of serum beta-carotene concentration, the D-xylose test, the breath-hydrogen test with either lactose or glucose as substrates, the detection of bile acid malabsorption with 75Se-HCAT and of protein-loosing enteropathies by means of the fecal clearance of alpha-1-antitrypsin.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Lembcke. 1994-10-18. [Simple tests for small intestinal function].. https://pubmed.ncbi.nlm.nih.gov/7973262/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Moment analysis of multibreath nitrogen washout in healthy preterm infants.

Moment analysis (MA) of multibreath nitrogen washout (MBNW) has not previously been applied to newborn infants. The aim of the present study was to adapt this method to healthy preterm infants using an improved technique suitable for small infants, and to determine reference values of MA. Twenty healthy preterm infants with a mean birth weight (+/-SD) of 1,666+/-402 g and a mean gestational age of 31.3+/-2.1 weeks were studied during their first 7-28 days of life. Computerized bedside equipment with very low dead space was constructed. The limits of normal variability were determined from results of duplicate studies. Outcome variables included functional residual capacity (FRC), the first-to-zeroth moment ratio (M1/M0), the second-to-zeroth moment ratio (M2/M0), and the lung clearance index (LCI). The starting point for MA had considerable impact on the results. Mean M1/M0 and M2/M0 were 2.18+/-0.18 and 8.71+/-1.24, respectively. No significant relation between moment ratios and weight, gender or age was found. Intrasubject coefficients of variation (CV) for M1/M0 (7.9+/-5.9%) and for M2/M0 (12.1+/-9.1%) and intersubject CV for M1/M0 (8%) and M2/M0 (14%) were similar to those reported in children and adults. Mean lung clearance index was 10.8+/-1.4 and intra- and intersubject CVs were 11.3+/-8.9% and 13%, respectively. Mean functional residual capacity (FRC) was 22.5+/-2.1 ml/kg. Mean intra- and intersubject CVs for FRC were 8.3% and 9%, respectively. We conclude that the MBNW test can be performed by a simple bedside method and that MA appears to be a suitable method for measuring gas mixing in preterm infants.

Breath Tests

[The effect of temperature and humidity on breath samples. Measurement of breath ethanol concentration in artificially respirated patients].

UNLABELLED: When looking for the possible cause of distortions in values measured for the determination of breath ethanol concentration (BEC) in artificially respirated patients, consideration must be given to the humidity and temperature of the gas examined. In the present study, the effects of humidified and warmed and of dry and cold air on the accuracy of a newly developed BEC measuring device, as compared to a reference model and to a conventional system, were examined in a lung model. METHODS: A temperature-regulated pediatric incubator was used containing a 10 I gas reservoir and a breath humidifier with temperature regulated water bath. This setup provided constant temperature and humidity in the gas examined during measurement period. In the 'expiration' the air was directed from the breath humidifier through a measuring unit via a 'mouthpiece' into the reference system (Alcotest 7110, Dräger Inc., Lübeck) and then out. The measuring unit consisted of sensors for the temperature and relative humidity, and of a connector for the three sample extraction systems (PES). PES I was the conventional system with a 100-cm gas-sample pipe (Alcomed 3010), PES II the newly developed system (AlcoMed 3011, both from Envitec, Wismar) with a 10-cm gas-sample pipe, and PES III with a 20-cm heated gas-sample pipe. During 'inspiration' 2 l of air was fed into the system to rinse the measuring unit and to fill the reservoir. 61 measurements were performed with dry and cold air, and 71 with humidified and warmed air, in the course of which the ethanol concentration was increased from 0 to 1.5/1000. Data were evaluated using regression analysis and the Bland & Altman method. RESULTS AND CONCLUSIONS: The constancy of the values set for temperature, relative humidity and absolute humidity in the lung model was given for all measurements. In the dry and cold air, the results from all three test systems coincided almost perfectly with the reference values. The measured BEC in the humidified and warmed air using sample-extraction systems II and III corresponded to a high degree with the reference, while in the case of PES I, only a moderate linear correlation was achieved. The temperature and humidity of the expired gas during artificial respiration influence the gas samples extracted for the purposes of BEC measurement. Newly developed sample-extraction systems II and III coincide with the reference system, even under respiration-simulated gas conditions.

Breath Tests

The alcohol breath test--a review.

The alcohol breath test (ABT) is evaluated for variability in response to changes in physiological parameters. The ABT was originally developed in the 1950s, at a time when understanding of pulmonary physiology was quite limited. Over the past decade, physiological studies have shown that alcohol is exchanged entirely within the conducting airways via diffusion from the bronchial circulation. This is in sharp contrast to the old idea that alcohol exchanges in the alveoli in a manner similar to the lower solubility respiratory gases (O2 and CO2). The airway alcohol exchange process is diffusion (airway tissue) and perfusion (bronchial circulation) limited. The dynamics of airway alcohol exchange results in a positively sloped exhaled alveolar plateau that contributes to considerable breathing pattern-dependent variation in measured breath alcohol concentration measurements.

Breath Tests