PubMed Health⌕ Search

PubMed · 7973582

[Therapeutic interventional sonography].

Abstract

By means of a review of the literature and basing on own results the possibilities of sonographically guided ontarget therapeutic interventions are disumed. Puncture of pleura, pericardium and in ascites can be performed with maximum safety. Therapeutic drainage of the effusions succeeds to practically 100 per cent. Punctures of custsare performed only if the lesions are symptomatic; sclerosing of renal cysts has a success rate of 65-80%, that of hepatic cysts up to 96%, ovarial and pancreatic cysts up to 90%. Since, however, the latter recur rapidly, permanent success can be rated as amounting to only 7%. Abscesses are punctured in installments or drained, depending on their size, shape and extension. Here, too, success rates achieved via on-target therapy guided by ultrasound are between 80 and 95%. First results obtained with ultrasound-guided on-target cholecystotomy in cases of colecystitis are encouraging; the disease pattern can be improved in at least 63% to 94% of cases, although the rate of complications is 8-12% and hence relatively high. Other techniques are also discussed, such as gastrostomy, nephrostomy, cholangiography and pancreaticography. Local on-target ultrasound-guided tumour therapy, especially of the primary hepatic cell carcinoma using highly concentrated alcohol results in a definitely longer survival period of the treated patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Weiss, A Weiss. 1994. [Therapeutic interventional sonography].. https://doi.org/10.1055/s-2007-1003956

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗