PubMed HealthSearch

PubMed · 7980932

Variations on cycle sequencing.

Abstract

Linear amplification or cycle sequencing is an advance that has made the use of automated fluorescent DNA sequencing instruments truly practical for large-scale genome analysis. We have investigated several variations of our standard cycle sequencing method. First, we have reduced the number of amplification cycles, which resulted in improved data quality and faster sequencing. Second, we have used different thermostable enzymes, which again improved data quality. Lastly, we have devised a method for precipitating reaction products in 96-tube trays. Together, these variations have allowed us to develop an improved cycle sequencing method that significantly increases sequencing throughput, improves efficiency and data quality, and reduces the cost of sequencing reactions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L L Fulton, R K Wilson. 1994. Variations on cycle sequencing.. https://pubmed.ncbi.nlm.nih.gov/7980932/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Gene amplification in the diagnosis of mycobacterial infections.

The number of importance of infections caused by Mycobacterium tuberculosis and other mycobacterial species is increasing. Since the detection and identification of mycobacteria by conventional laboratory methods (cultivation, staining, and biochemical tests) is a slow and complex procedure, rapid diagnostic methods are urgently needed. Several amplification methods based on different techniques have been applied in the detection of mycobacteria directly from clinical specimens. Most experience has been obtained from different polymerase chain reaction (PCR) assays and their general performance is good. However, their sensitivity in the analysis of samples containing small amounts of mycobacteria or samples containing inhibitory substances has been low. Furthermore, the risk of false positives caused by contamination is high, and the clinical relevance of the results may be unclear. Thus, these gene amplification techniques are a valuable adjunct to the diagnosis of mycobacteria, but so far they cannot replace conventional microbiological methods.

Gene Amplification

MDM2 amplification, P53 mutation, and accumulation of the P53 gene product in malignant fibrous histiocytoma.

Fifty-two cases of malignant fibrous histiocytoma (MFH) were evaluated for amplification of the MDM2 gene, mutation of the P53 gene, accumulation of the P53 gene product, and their relation to disease-free and overall survival. All tests were carried out on formalin-fixed, paraffin-embedded tissue samples. Amplification of the MDM2 gene was detected in 15 of 52 cases (29%). Six of 52 cases (12%) demonstrated abnormalities of the P53 gene. Sequence analysis detected point mutations in four cases and a 1-base pair deletion in one case, whereas differential polymerase chain reaction (dPCR) indicated that the P53 gene had been entirely deleted in one case. Eight of 52 cases (15%) demonstrated staining for the P53 protein in >10% of tumor cells. The presence of MDM2 amplification did not have a significant effect on either disease-free or overall survival. Patients with accumulation of the P53 gene product did not differ in disease-free or overall survival from patients without P53 accumulation. Survival also was not significantly different in patients with genetic aberration in P53. However, when the patients were stratified by histologic grade, the results indicated that patients with alterations in the P53 gene may have shorter overall survival.

Gene Amplification