PubMed Health⌕ Search

PubMed · 7984373

Ossiculoplasty with semibiologic and composite prostheses.

Abstract

The Lippy-modified Robinson prosthesis has been used for years in revision stapedectomy and has proved successful in reconstructing the absent lenticular process. When this technique fails, an ossicle cup prosthesis can be used. The ossicle cup and columella have been used for 20 years with continuing success. The advantages of the semibiologic prostheses are as follows: The prosthesis can be sized as each case requires, giving a variable height above the remaining stapes. The prosthesis is designed not to touch the promontory or facial nerve canal. The synthetic portion of the semibiologic prosthesis does not touch the tympanic membrane. An efficient perpendicular action is achieved from the tympanic membrane to the stapes footplate. The prosthesis remains in place during tympanic membrane movement. A stable dynamic joint is provided with the stapes capitulum (ossicle cup). A safe platform is provided that distributes the weight of the assembly prosthesis over the entire stapes footplate (ossicle columella). Although both semibiologic prostheses are used routinely for partial and total ossicular replacement, other troublesome and technically difficult ossicular reconstruction problems can also be solved by the adaptability of the synthetic portion of the prosthesis. Because the synthetic portion of the prosthesis can be modified by notching, shaping, and trimming, the following problems can be overcome: A laterally healed tympanic membrane can be reached by increasing the length of the synthetic shaft. In the absence of the stapes capitulum, the cup is notched in two places (180 degrees apart) to fit the shoulders of the remaining stapes. Remaining crura on the footplate can be bypassed by trimming the synthetic footplate to fit in between the crura. The stapes with a low profile can be utilized by increasing the length of the synthetic shaft. An abnormal stapedial tendon attachment to the stapes capitulum can be overcome with a single notch in the cup. An overhanging facial nerve can usually be bypassed by the narrow design of the ossicle columella. The future of ossiculoplasty will rest more on the solution of ancillary problems than on ossiculoplasty techniques. These troublesome ancillary problems include eustachian tube dysfunction, cholesteatoma control, mucosa regeneration, and fibrosis during the healing process. The self-correcting process of ossiculoplasty is an evolutionary process, and the small surgical steps taken are slowly incorporated into surgical principles. Incorporating a synthetic prosthesis within a natural or synthetic ossicle is a logical and evolutionary step in the science of ossicular reconstruction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A G Schuring. 1994. Ossiculoplasty with semibiologic and composite prostheses.. https://pubmed.ncbi.nlm.nih.gov/7984373/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development of a 3D cell culture system for investigating cell interactions with electrospun fibers.

There are many variables to be considered in studying how cells interact with 3D scaffolds used in tissue engineering. In this study we investigated the influence of the fiber diameter and interfiber spaces of 3D electrospun fiber scaffolds on the behavior of human dermal fibroblasts. Fibers of two dissimilar model materials, polystyrene and poly-L-lactic acid, with a broad range of diameters were constructed in a specifically developed 3D cell culture system. When fibroblasts were introduced to freestanding fibers, and encouraged to "walk the plank," a minimum fiber diameter of 10 microm was observed for cell adhesion and migration, irrespective of fiber material chemistry. A distance between fibers of up to 200 microm was also observed to be the maximum gap that could be bridged by cell aggregates--a behavior not seen in conventional 2D culture. This approach has identified some basic micro-architectural parameters for electrospun scaffold design and some key differences in fibroblast growth in 3D. We suggest the findings will be of value for optimizing the integration of cells in these scaffolds for skin tissue engineering.

Biocompatible Materials↗

Improved catalytic properties of immobilized lipases by the presence of very low concentrations of detergents in the reaction medium.

The addition of a very small concentration of a detergent (in many instances under the critical micellar concentration (cmc)) has been found to greatly increase the activity of immobilized lipases, using those from Pseudomonas fluorescens (PFL) and Candida antarctica (isoform B) as model enzymes. However, the detergents may also have a negative effect on enzyme activity; in fact, for all enzyme preparations and substrates the activity/detergent concentration curve reached a maximum value and started to decrease, in many instances even under the initial value. The concentration and nature of the detergent (SDS, CTAB, Triton X-100, or X-45) that permitted the maximum hyperactivation was different depending on the substrate. The best hyperactivation values promoted by the presence of detergent were over a 20-fold factor. The presence of detergents permitted the inhibition of lipases by irreversible covalent inhibitors (e.g., 4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride) (AEBSF) while the enzyme, in the absence of detergent, is not inhibited by these irreversible inhibitors. This suggested that the main effect of the detergents is to shift the conformational equilibrium of lipases toward the open form. Moreover, the presence of detergents also permitted to improve the enantioselectivity exhibited by the immobilized lipases in some cases. For example, the enantioselectivity of PFL-glyoxyl agarose increased from 40 to more than 100 in the hydrolysis of (+/-)-2-hydroxy-4-phenylbutyric acid ethyl ester by using 0.1% CTAB.

Biocompatible Materials↗

Development of wollastonite-poly(ethylmethacrylate co-vinylpyrrolidone) based materials for multifunctional devices.

The manufacturing of a composite made of a synthetic bioactive ceramic, pseudowollastonite (psW), and a bioresorbable copolymer ethylmethacrylate-vinylpyrrolidone (EMA/VP) is presented in this article. psW porous blocks were produced by dipping an open porous polyurethane foam in a psW containing slurry. A 40/60 wt % EMA/VP monomers mixture was poured on the blocks, and free radical polymerization initiated by azobis(isobutyronitrile) at 50 degrees C. Disks of 1 mm height were obtained by cutting the composite with a diamond saw, and bioresorption and bioactivity of the specimens were tested by immersion of the disks into SBF. A ceramic/polymer weight ratio of 72/28, greater than the usually achievable ratio by polymeric solidification of slurries of monomers charged with a powdered solid component, has been obtained. The system is bioactive and does not change the pH of the medium during the degradation test.

Biocompatible Materials↗