PubMed HealthSearch

PubMed · 7995441

A method for making predictable and highly accurate provisionals.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E R Stephan. 1994. A method for making predictable and highly accurate provisionals.. https://pubmed.ncbi.nlm.nih.gov/7995441/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radiographic inspection of dental castings.

Underdimensioning may adversely affect the clinical use of a crown or bridge. Insufficient dimensions may be due to inadequate modelling or deficiencies caused by the casting process. The dimensions of cast objects are measured mechanically using a calliper. This method has often proved to be insufficient in detecting areas of too small dimensions. This paper presents a non-destructive method of inspecting dental castings using radiography. The occlusal thickness of a random sample of 150 crowns made during regular clinical treatment in our department was inspected mechanically and radiographically. We found that 19% of the crowns were only 0.1 mm thick or less at the thinnest spot, 18% were between 0.1 and 0.2 mm and 9% were between 0.2 and 0.3 mm. In comparison to mechanical examination, radiographic inspection usually showed smaller values.

Crowns

Leakage associated with load fatigue-induced preliminary failure of full crowns placed over three different post and core systems.

Thirty-six maxillary central incisors were endodontically treated and restored with a post and core and cast crown. Three different post and core systems were evaluated. Restored teeth were fatigue-loaded until preliminary failure of the casting occurred as detected by a strain gauge bonded across the lingual margin of the cast crown. After preliminary failure, fatigue loading was continued for 100,000 load cycles with the crown margin exposed to basic fuschin dye. Teeth were then immersed in dye for 24 h, sectioned, and evaluated for leakage. There was no significant difference in the number of load cycles required to cause preliminary failure among the three post and core systems. Leakage occurred in all three groups, with no significant difference between groups. The occurrence of preliminary failure is clinically undetectable, yet it allows leakage between the restoration and tooth that may extend down the prepared post space.

Crowns

Bacterial leakage into and from prefabricated screw-retained implant-borne crowns in vitro.

A mean gap of less than 4 microm following laboratory procedures and continuous loading was demonstrated in prefabricated crowns of the Ha-Ti implant system in earlier studies. The clinical relevance of such high precision in maintaining inflammation free marginal mucosa is yet to be determined. In this present investigation, the complete assembly of Ha-Ti implants including prefabricated screw-retained crowns was tested for bacterial leakage under controlled conditions in vitro. The gaps were shown not to be a barrier for Staphylococcus aureus which were used as test bacteria. Bacterial leakage through these gaps from the environment to the interior of the assembly and vice versa was observed within 24-120 h. The main path of bacterial penetration was possibly found to be through the transversal screw hole and not through the marginal gap of the prefabricated crowns.

Crowns