PubMed Health⌕ Search

PubMed · 7997090

Single-shot-double-echo EPI.

Abstract

Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously. This single-shot-double-echo EPI approach offers a variety of useful applications such as varying image contrast, obtaining flow or diffusion information, improving image resolution or circumventing T*2 requirements in single shot EPI. Benefits and limits of this technique are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Börnert, D Jensen. 1994. Single-shot-double-echo EPI.. https://doi.org/10.1016/0730-725x(94)91234-n

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Enhanced bio-manufacturing through advanced multivariate statistical technologies.

The paper describes the interrogation of data, from a reaction vessel producing an active pharmaceutical ingredient (API), using advanced multivariate statistical techniques. Due to the limited number of batches available, data augmentation was used to increase the number of batches thereby enabling the extraction of more subtle process behaviour from the data. A second methodology investigated was that of multi-group modelling. This allowed between cluster variability to be removed, thus allowing attention to focus on within process variability. The paper describes how the different approaches enabled the realisation of a better understanding of the factors causing the onset of an impurity formation to be obtained as well demonstrating the power of multivariate statistical data analysis techniques to provide an enhanced understanding of the process.

Artifacts↗

Interpretation of atypical patterns encountered when using a flow cytometry-based method to detect residual leukocytes in leukoreduced red blood cell components.

BACKGROUND: Universal leukoreduction of blood components is becoming the standard of care. Flow cytometry methods are being used for quality control of the leukoreduction process. METHODS: We provide an atlas of atypical flow cytograms generated by a commercial LeucoCOUNT assay that was used to enumerate residual leukocytes in leukoreduced red blood cell components. Numeric results are derived from a flow cytogram generated by the assay. RESULTS: Three types of atypical flow cytogram patterns were observed during process validation or routine quality control of leukoreduced red blood cell components. (a) Fixation artifact: Fixation of control or test samples can alter the staining intensity compared with fresh cells. (b) "Rain" pattern: Flow cytometry methods count slightly damaged leukocytes not removed during leukoreduction. Slightly damaged leukocytes appear on a flow cytogram like "rain" falling from a well-defined "cloud" of intact residual leukocytes. Discrepancies between automated flow cytometry results and subjective manual counting methods can occur. (c) Autofluorescence-debris pattern: Cell debris and age-related changes in the sample can cause shifts in the fluorescence staining pattern, resulting in erroneous test results. CONCLUSION: Review of flow cytograms is essential for accurate reporting of flow cytometry-based methods for enumerating residual leukocytes in leukoreduced blood components.

Artifacts↗