Shaping static elbow torque-angle relationships by spinal cord circuits: a theoretical study.

Abstract

Static torque-angle relationships (invariant characteristics) as measured by Feldman [Feldman A. G. (1980) Neuroscience 5, 81-90] at the human elbow joint for constant descending excitatory drive have a monotonic convex shape determining joint angle-dependent stiffness. In contrast, for constant activation of elbow flexors, the torque increases, peaks and decreases again with increasing angle because of related moment arm alterations [Hasan Z. and Enoka R. M. (1985) Expl Brain Res. 59, 441-450]. Conversion of such constant-excitation torque-angle shapes into an invariant characteristic might result from action of the stretch reflex which adds excitation with increasing joint angle. To test whether a simple linear model of the stretch reflex could convert constant excitation torque-angle relationships into invariant characteristics, the following assumptions were made. (1) Muscle fibre length increases linearly with joint angle. (2) Reflex muscle excitation (electromyogram) is linearly related to muscle (fibre) length. With these assumptions, invariant characteristic shape cannot be derived from constant excitation torque-angle relationships because it would be sigmoid at low and nearly straight at large joint angles, whilst real flexor invariant characteristics are more convex at large than small angles. It is suggested that recurrent inhibition via Renshaw cells contributes to bend the invariant characteristics into their right shape. Renshaw cells show a nonlinear saturating dependence on motor axon input rate and amount of excitation, i.e. number of active axon collateral synapses. These relationships can contribute to shape motoneuron output so as to yield convex invariant characteristics. Whilst it is not quite clear whether the gain of recurrent inhibition from and to skeleto-motoneurons is high enough to co-determine the invariant characteristic shape significantly, recurrent inhibition of Ia inhibitory interneurons mediating reciprocal inhibition between antagonists is supposed to be quite strong and may influence joint stiffness by interacting with reciprocal inhibition. The arguments presented here extend those of Feldman and co-workers concerning the role of recurrent inhibition and in addition provide a possible explanation for the functional role of mutual inhibition between Renshaw cells. Together with reflex feedback, recurrent inhibition thus contributes to fine-regulate force output and joint stiffness. To account for this cooperation and to make another step towards a general theory of spinal cord circuits, major traits of a new concept are briefly outlined.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Windhorst. 1994. Shaping static elbow torque-angle relationships by spinal cord circuits: a theoretical study.. https://doi.org/10.1016/0306-4522(94)90189-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗