Digital image processing. I. Evaluation of gray level correction methods in vitro.

Abstract

The aims of this study were a) to assess in an in vitro model the amount of density changes measured in digitally subtracted images due to electronic noise and image alignment error, and b) to test the accuracy of different gray level correction procedures in the reduction of densitometric image mismatches. A section of a pig mandible in which a hollow cylinder ITI Bonefit implant had been placed was used to obtain pairs of standardized radiographs. Series of radiographs were obtained with different exposure times (0.34, 0.39, 0.44, 0.51, 0.58 s). The radiographs were captured through a video camera, digitized and stored in a personal computer. The same radiographic image was recorded and subtracted from itself 10 times to study the error of the method due to electronic transformations of the images and image alignment. The noise due to the analog-to-digital transformation of the radiographic images was calculated to be +/- 2 gray levels i.e., 2% of the scale of gray levels. This kind of error was reduced up to 40% by capturing the images more than once and averaging the values per pixel. The manual superimposition of the images to be subtracted caused an increase of the error to +/- 3 gray levels (2.7%). Seven methods of gray level correction based either on a linear least squares approximation or on the cumulative density function (CDF) were tested. The group based on the CDF algorithm gave significantly better results than any other method. Pixels yielding differences smaller or equal to +/- 7 gray levels (5.5% of the scale of gray levels) should be excluded from further calculations in order to eliminate (false-positive) errors due to the normalizing algorithms. Furthermore, the CDF method on an arbitrarily chosen area of the image or on the wedge seems to give to subtraction images the ability of revealing real subtle changes in tissue density (fewer false-negative errors). The use of reference structures did not futher improve the ability of the normalization methods to correct gray level mismatches between radiographic pairs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Fourmousis, U Brägger, W Bürgin, M Tonetti, N P Lang. 1994. Digital image processing. I. Evaluation of gray level correction methods in vitro.. https://doi.org/10.1034/j.1600-0501.1994.050105.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗