First-pass ventricular ejection fraction using a single-crystal nuclear camera.

Abstract

UNLABELLED: The purpose of the study was to evaluate the reliability of ejection fractions obtained from first-pass radionuclide ventriculography with a large field-of-view tomographic single-crystal gamma camera. METHODS: A SPECT camera had its electronics redesigned to improve counting efficiency and was equipped with an experimental ultra-high sensitivity collimator. Left ventricular ejection fraction (LVEF) was measured in 28 patients by 30 degrees RAO first-pass imaging and by "best septal view" LAO planar equilibrium radionuclide ventriculography on a conventional small field of view Anger camera. For 28 other patients, first-pass ejection fractions were compared to multicrystal gamma camera values. Visual analysis was performed to judge clinical acceptability of first-pass images for identification of wall-motion abnormalities. RESULTS: Linear regression analysis of first-pass against equilibrium ejection fraction demonstrated good correlation (r = 0.92; slope = 0.90; intercept = 3.8; s.e.e. = 6.4%). First-pass ejection fraction values also correlated linearly with multicrystal camera values for the left ventricle (r = 0.94; slope = 1.05; intercept = 1.3; s.e.e. = 5.3%). For a subgroup of 19 patients, single-crystal camera right ventricle ejection fraction demonstrated good correlation with multicrystal camera values (r = 0.82; slope = 1.15; intercept = 1.3; s.e.e. = 6.1%). Interobserver variability correlated as r = 0.99 for LVEF ejection fraction and r = 0.92 for RVEF. Chi-square analysis of single-crystal first-pass image visual scores versus those from the gated equilibrium acquisitions showed close agreement (p < 10(-8)). CONCLUSIONS: The evaluated camera/collimator system measured left and right ventricular ejection fraction accurately. Lung frame correction and dual regions were superior to paraventricular background correction and a fixed end-diastolic region.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Nichols, E G DePuey, N Gooneratne, H Salensky, M Friedman, S Cochoff. 1994. First-pass ventricular ejection fraction using a single-crystal nuclear camera.. https://pubmed.ncbi.nlm.nih.gov/8046481/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging.

PURPOSE: To investigate in three institutions, The Netherlands Cancer Institute (Antoni van Leeuwenhoek Huis [AvL]), Dr. Daniel den Hoed Cancer Center (DDHC), and Dr, Bernard Verbeeten Institute (BVI), how much the patient setup accuracy for irradiation of prostate cancer can be improved by an offline setup verification and correction procedure, using portal imaging. METHODS AND MATERIALS: The verification procedure consisted of two stages. During the first stage, setup deviations were measured during a number (Nmax) of consecutive initial treatment sessions. The length of the average three dimensional (3D) setup deviation vector was compared with an action level for corrections, which shrunk with the number of setup measurements. After a correction was applied, Nmax measurements had to be performed again. Each institution chose different values for the initial action level (6, 9, and 10 mm) and Nmax (2 and 4). The choice of these parameters was based on a simulation of the procedure, using as input preestimated values of random and systematic deviations in each institution. During the second stage of the procedure, with weekly setup measurements, the AvL used a different criterion ("outlier detection") for corrective actions than the DDHC and the BVI ("sliding average"). After each correction the first stage of the procedure was restarted. The procedure was tested for 151 patients (62 in AvL, 47 in DDHC, and 42 in BVI) treated for prostate carcinoma. Treatment techniques and portal image acquisition and analysis were different in each institution. RESULTS: The actual distributions of random and systematic deviations without corrections were estimated by eliminating the effect of the corrections. The percentage of mean (systematic) 3D deviations larger than 5 mm was 26% for the AvL and the DDHC, and 36% for the BVI. The setup accuracy after application of the procedure was considerably improved (percentage of mean 3D deviations larger than 5 mm was 1.6% in the AvL and 0% in the DDHC and BVI), in agreement with the results of the simulation. The number of corrections (about 0.7 on the average per patient) was not larger than predicted. CONCLUSION: The verification procedure appeared to be feasible in the three institutions and enabled a significant reduction of mean 3D setup deviations. The computer simulation of the procedure proved to be a useful tool, because it enabled an accurate prediction of the setup accuracy and the required number of corrections.

Feasibility Studies

Evaluation and scoring of radiotherapy treatment plans using an artificial neural network.

PURPOSE: The objective of this work was to demonstrate the feasibility of using an artificial neural network to predict the clinical evaluation of radiotherapy treatment plans. METHODS AND MATERIALS: Approximately 150 treatment plans were developed for 16 patients who received external-beam radiotherapy for soft-tissue sarcomas of the lower extremity. Plans were assigned a figure of merit by a radiation oncologist using a five-point rating scale. Plan scoring was performed by a single physician to ensure consistency in rating. Dose-volume information extracted from a training set of 511 treatment plans on 14 patients was correlated to the physician-generated figure of merit using an artificial neural network. The neural network was tested with a test set of 19 treatment plans on two patients whose plans were not used in the training of the neural net. RESULTS: Physician scoring of treatment plans was consistent to within one point on the rating scale 88% of the time. The neural net reproduced the physician scores in the training set to within one point approximately 90% of the time. It reproduced the physician scores in the test set to within one point approximately 83% of the time. CONCLUSIONS: An artificial neural network can be trained to generate a score for a treatment plan that can be correlated to a clinically-based figure of merit. The accuracy of the neural net in scoring plans compares well with the reproducibility of the clinical scoring. The system of radiotherapy treatment plan evaluation using an artificial neural network demonstrates promise as a method for generating a clinically relevant figure of merit.

Feasibility Studies

Diagnostic accuracy in remote expert consultation using standard video-conference technology.

An international multicenter study (Germany, Sweden, and Switzerland) was performed to investigate the feasibility and diagnostic reliability of standard video-conferencing (VC) technology for remote expert consultation in radiology. Three high-spatial-resolution films (hand-bone, mammography, chest) and two low-spatial-resolution image sets (liver CT and MRI) were studied (total 446 images taken from different examinations). The images were recorded by a video camera, transmitted via public broadband networks, and displayed on a video monitor. The resolution of the recorded images varied from 2.4 lp/mm to 4.8 lp/mm at maximum zoom. After 3-4 months, the images were reexamined using conventional light-box reading. Diagnostic reliability was evaluated by receiver operating characteristics (ROC) analysis. With video conferencing, there was a noticeable loss of diagnostic accuracy for the high-spatial-resolution films, whereas for liver CT and liver MRI images VC reading seemed to be satisfactory (average area value difference < 0.02).

Feasibility Studies