Demand-flow airway pressure release ventilation as a partial ventilatory support mode: comparison with synchronized intermittent mandatory ventilation and pressure support ventilation.

Abstract

OBJECTIVE: To evaluate airway pressure release ventilation as a partial ventilatory support mode by comparing a demand-flow airway pressure release ventilation system with synchronized intermittent mandatory ventilation and pressure support ventilation. DESIGN: Prospective, nonrandomized, cross-over trial. SETTING: Medical intensive care unit in a university medical center. PATIENTS: Sixteen consecutive patients without chronic obstructive pulmonary disease with mechanical ventilatory support of 25% to 75% of total minute ventilation on synchronized intermittent mandatory ventilation, or 25% to 75% of maximal pressure support level on pressure support ventilation. INTERVENTIONS: Each mode of mechanical ventilation was supplied to patients with comparable levels of partial support for 30 mins. MEASUREMENTS AND MAIN RESULTS: Among three different modes, demand-flow airway pressure release ventilation achieved the lowest peak airway pressure (airway pressure release ventilation 9.1 +/- 2.6 cm H2O; pressure support ventilation 18.4 +/- 4.6 cm H2O; synchronized intermittent mandatory ventilation 34.8 +/- 7.7 cm H2O; p < .001). Hemodynamic status and oxygenation status were similar among these three modes. Five (31%) of the 16 patients felt that demand-flow airway pressure release ventilation was a less comfortable mode than synchronized intermittent mandatory ventilation or pressure support ventilation. This finding had no clear correlation with their duration of airway pressure release, preset machine deflation rate, or inspiratory/expiratory ratio of machine breath. Gross asynchrony of effort and ventilator cycling was noticed in two (13%) patients while they were receiving demand-flow airway pressure release ventilation. CONCLUSIONS: We conclude that for patients who do not have chronic obstructive pulmonary disease, demand-flow airway pressure release ventilation can provide effective partial ventilatory support with lower peak airway pressure when compared with pressure support ventilation and synchronized intermittent mandatory ventilation. However, this airway pressure release ventilation system may be less comfortable than the other two modes, and asynchrony may occur in some patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A A Chiang, A Steinfeld, C Gropper, N MacIntyre. 1994. Demand-flow airway pressure release ventilation as a partial ventilatory support mode: comparison with synchronized intermittent mandatory ventilation and pressure support ventilation.. https://doi.org/10.1097/00003246-199409000-00013. https://pubmed.health/record/pubmed%3A8062566/demand-flow-airway-pressure-release-ventilation-as-a-partial-ventilatory-support-mode-comparison-wit

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Molecular heterochrony and the evolution of sociality in bumblebees (Bombus terrestris).

Sibling care is a hallmark of social insects, but its evolution remains challenging to explain at the molecular level. The hypothesis that sibling care evolved from ancestral maternal care in primitively eusocial insects has been elaborated to involve heterochronic changes in gene expression. This elaboration leads to the prediction that workers in these species will show patterns of gene expression more similar to foundress queens, who express maternal care behaviour, than to established queens engaged solely in reproductive behaviour. We tested this idea in bumblebees (Bombus terrestris) using a microarray platform with approximately 4500 genes. Unlike the wasp Polistes metricus, in which support for the above prediction has been obtained, we found that patterns of brain gene expression in foundress and queen bumblebees were more similar to each other than to workers. Comparisons of differentially expressed genes derived from this study and gene lists from microarray studies in Polistes and the honeybee Apis mellifera yielded a shared set of genes involved in the regulation of related social behaviours across independent eusocial lineages. Together, these results suggest that multiple independent evolutions of eusociality in the insects might have involved different evolutionary routes, but nevertheless involved some similarities at the molecular level.

Analysis of Variance↗

Confidence intervals for the standardized effect arising in the comparison of two normal populations.

Confidence intervals for a standardized effect are derived after stabilizing the variance of the Welch t-statistic. Simulation studies demonstrate the viability of the resulting intervals for a wide range of parameter values and sample sizes as small as five. The methodology is extended to the combination of results from several studies, so as to obtain a confidence interval for a representative standardized effect for all the studies. The methods are illustrated on a recent meta-analytic study of systolic blood pressure reduction during a weight reducing regime, as well as the classical Mumford data on psychological intervention and hospital length of stay.

Analysis of Variance↗