PubMed Health⌕ Search

PubMed · 8066908

[Hepatitis C].

Abstract

Hepatitis C virus (HCV) was recognized in 1989 as the main cause of transfusion-related hepatitis non-A, non-B (HNANB) as well as sporadically-acquired HNANB infections. The HCV genome has been sequenced but the virus has not yet been visualized. Anti-HCV antibody tests have been developed, namely enzyme-linked immunosorbent assays (ELISA) for screening and recombinant immunoblot assay (RIBA) for confirmative testing of ELISA positive results. Since May 1991 all Danish blood donations have been tested for anti-HCV antibodies. Approximately 0.04% of Danish blood donors are 4-RIBA positive and have signs of chronic HCV infection based on ALT, HCV-RNA or histological findings. High-risk groups are intravenous drug abusers, haemophiliacs, haemodialysis patients and recipients of multiple blood transfusions. Approximately one third of the cases are sporadic, i.e. without obvious risk factors. Sexual transmission of HCV may occur, but this route is uncommon. More than half of the patients with acute HCV infection progress to chronic hepatitis C. Of these a considerable proportion develops cirrhosis and some eventually hepatocellular carcinoma. At present interferon (IFN) is the only registered therapy against chronic hepatitis C. Approximately half of the patients respond to treatment. The majority, however, relapse after stopping IFN treatment and only 20% maintain their response.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H B Krarup, K Krogsgaard. 1994-07-11. [Hepatitis C].. https://pubmed.health/record/pubmed%3A8066908/hepatitis-c

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Hepatitis C Virus Enhances Lysosome-Associated Membrane Protein 2 A Transcription Through Nuclear Factor Erythroid 2-Related Factor 2 to Support Viral Replication.

Hepatitis C virus (HCV) establishes persistent infection by rewiring host stress-response pathways. Chaperone-mediated autophagy (CMA) contributes to HCV replication, but it remains unclear whether HCV regulates lysosome-associated membrane protein 2 A (LAMP-2A), the rate-limiting receptor for CMA. Here, we examined LAMP-2A regulation in HCV-infected Huh-7.5 cells. HCV infection increased LAMP-2A promoter activity, mRNA, and protein abundance, indicating transcriptional upregulation. Among candidate stress-responsive transcription factors, nuclear factor erythroid 2-related factor 2 (NRF2), hypoxia-inducible factor 1α (HIF-1α), and nuclear factor of activated T cells 1 (NFAT1) were elevated in infected cells. However, promoter mutagenesis identified NRF2 as the principal direct regulator. Mutation of the NRF2-responsive antioxidant response element markedly reduced basal and HCV-induced LAMP-2A promoter activity. Chromatin immunoprecipitation assays revealed NRF2 association with the LAMP-2A promoter, and HCV infection increased nuclear accumulation and Ser40 phosphorylation of NRF2. Functionally, shRNA-mediated knockdown of LAMP-2A reduced intracellular HCV RNA and protein levels. These findings identify an NRF2-LAMP-2A regulatory axis engaged during HCV infection and support a model in which HCV upregulates LAMP-2A to establish a cellular environment favorable for viral replication.

Hepacivirus↗

Evaluation of the Abbott RealTime HCV assay for quantitative detection of hepatitis C virus RNA.

BACKGROUND: The Abbott RealTime HCV assay for quantitative detection of HCV RNA has recently been introduced. OBJECTIVES: In this study, the performance of the Abbott RealTime HCV assay was evaluated and compared to the COBAS AmpliPrep/COBAS TaqMan HCV test. STUDY DESIGN: Accuracy, linearity, interassay and intra-assay variations were determined, and a total of 243 routine clinical samples were investigated. RESULTS: When accuracy of the new assay was tested, the majority of results were found to be within +/-0.5 log(10) unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve up to 1.0 x 10(6)IU/ml. The interassay variation ranged from 15% to 32%, and the intra-assay variation ranged from 5% to 8%. When clinical samples were tested by the Abbott RealTime HCV assay and the results were compared with those obtained by the COBAS AmpliPrep/COBAS TaqMan HCV test, the results for 93% of all samples with positive results by both tests were found to be within +/-1.0 log(10) unit. The viral loads for all patients measured by the Abbott and Roche assays showed a high correlation (R(2)=0.93); quantitative results obtained by the Abbott assay were found to be lower than those obtained by the Roche assay. CONCLUSIONS: The Abbott RealTime HCV assay proved to be suitable for use in the routine diagnostic laboratory. The time to results was similar for both of the assays.

Hepacivirus↗