PubMed Health⌕ Search

PubMed · 8079620

Electrophysiological methods in early glaucoma detection.

Abstract

Electrophysiological methods like pattern electroretinogram and pattern visual evoked potentials may be the best approach for early glaucoma detection, as they have demonstrated to be sensitive to the ganglion cells functional changes. Reported values of both P50 and N95 pattern electroretinogram components differ widely, a fact perhaps related to a heterogeneous grouping of patients suffering from ocular hypertension and glaucoma, rather than to the type of technique utilized. This study is based on a total of 42 subjects: 14 normals, 16 subjects suffering from ocular hypertension, and 12 patients with glaucoma, with 79 eyes examined. Pattern electroretinogram and pattern visual evoked potentials were used as successive techniques. Setting condition for pattern electroretinogram, such as low temporal frequency (2 Hz), 30 min check size, high contrast (99%) and luminance (93 cd/m2), identified the N95 component as the best index for early glaucoma detection. In the control group N95 mean amplitude was 1.62 muV +/- 0.59 SD and showed almost significant difference with ocular hypertension (p = 0.07) and highly significant difference with the glaucoma group (p < 0.01), with decrement of 58.6% in the glaucoma group. P50 mean amplitude, on the contrary, did not show significant differences among the groups (Newman-Keul test), its reduction in glaucoma being 28%. The mean pattern visual evoked potentials latency was alos highly significant between glaucoma and control groups, but not between ocular hypertension and control groups; the mean amplitude did not show significant differences. A proportion of 26.6% abnormal pattern electroretinogram was found in the group suspected of having glaucoma where conventional methods had proved normal.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F J Fernández-Tirado, P Uclés, L Pablo, F M Honrubia. 1994. Electrophysiological methods in early glaucoma detection.. https://doi.org/10.1111/j.1755-3768.1994.tb05011.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acute effects of estrogen on neuronal physiology.

It has been known for more than 30 years that estrogen can alter the intrinsic and synaptic physiology of neurons within minutes. The physiological significance of these acute effects has been unclear, however, because some effects require higher concentrations of estrogen than are detected in plasma, and because estrogen secreted by the ovary rises and falls over a time course of days, not minutes. These concerns may be answered by new research demonstrating that estrogen is produced at high levels within the brain itself, and that production of estrogen in the brain may be regulated by neuronal activity. Additionally, recent studies indicate that classical estrogen receptor proteins are found not only in the nucleus where they regulate gene expression but also at extranuclear sites, including at synapses. These findings, together with evidence for new types of extranuclear estrogen receptors, suggest that estrogen might act directly at synapses to activate second messenger signaling, thereby rapidly altering neuronal excitability, synaptic transmission, and/or synaptic plasticity.

Electrophysiology↗