PubMed HealthSearch

PubMed · 8121317

Model experiments on measuring flow in microvessels using tracers.

Abstract

Most techniques for measuring plasma or red cell flow velocity within microvessels rely on determining the transit time of a tracer to transverse the distance between two monitoring sites within a vessel. In principle, proper transit time determinations require flow-weighted sampling of the tracer at monitoring sites. In practical application of the tracer technique, however, trace sampling at monitoring sites is not flow-weighted but is area-weighted, and hence elapsed transient time can only be estimated from tracer data. We previously showed theoretically (Microvasc. Res. 40, 394-411, 1990) that the flow velocity determined under these conditions can differ appreciably from the actual mean flow velocity of the carrier fluid within the microvessel. Nevertheless, trace mean flow velocity does approach that of the fluid when tracer velocity is measured past a finite distance from the microvessel entrance. In this study, we examined the tracer measurement of flow experimentally using a physical model. We perfused single glass microvessels and simple fabricated microvessel networks with distilled water at physiological flow rates. Mean tracer velocity (Vd) was determined at several axial locations within the microvessels using injected Evans blue dye. At each location Vd was determined in a manner consistent with usual application of the tracer flow measurement technique. Actual mean flow velocity (Va) was determined from the measured effluent flow rates discharged from each microvessel. Our experimental results confirm the existence of an appreciable velocity measurement error (VME) associated with the tracer technique. The VME behavior was consistent with our original theoretical analysis. Vd was significantly smaller than Va within a finite length of vessel near the entrance, but approached and became equal to Va past this length. Furthermore, even under conditions where the VME was negligible at the end of a parent microvessel, a new and appreciable VME arose within the connecting downstream daughter microvessels. These results underscore that tracer mean flow velocity as obtained in normal implementation of the tracer technique can differ from that for the fluid itself within a microvascular network.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W J Federspiel, K Malai. 1993. Model experiments on measuring flow in microvessels using tracers.. https://doi.org/10.1006/mvre.1993.1057

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Assessment of left internal mammary artery grafts using dipyridamole Doppler echocardiography.

Color Doppler echocardiography of the left mammary artery was combined with dipyridamole testing in order to assess the presence of significant (>70%) graft stenosis in 87 patients with a mammary artery graft to the left anterior descending coronary artery presenting with chest pain. Occluded grafts are detected by absent diastolic flow velocities at baseline, whereas the response of the diastolic flow velocity to dipyridamole distinguishes patients with critical versus noncritical stenosis of a patent graft.

Blood Flow Velocity

Doppler tissue imaging: a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures.

OBJECTIVES: This investigation was designed 1) to assess whether the early diastolic velocity of the mitral annulus (Ea) obtained with Doppler tissue imaging (DTI) behaves as a preload-independent index of left ventricular (LV) relaxation; and 2) to evaluate the relation of the mitral E/Ea ratio to LV filling pressures. BACKGROUND: Recent observations suggest that Ea is an index of LV relaxation that is less influenced by LV filling pressures. METHODS: One hundred twenty-five study subjects were classified into three groups according to mitral E/A ratio, LV ejection fraction (LVEF) and clinical symptoms: 34 asymptomatic subjects with a normal LVEF and an E/A ratio > or =1; 40 with a normal LVEF, an E/A ratio <1 and no heart failure symptoms (impaired relaxation [IR]); and 51 with heart failure symptoms and an E/A ratio >1 (pseudonormal [PN]). Ea was derived from the lateral border of the annulus. A subset of 60 patients had invasive measurement of pulmonary capillary wedge pressure (PCWP) simultaneous with Doppler echocardiographic DTI. RESULTS: Ea was reduced in the IR and PN groups compared with the group of normal subjects: 5.8 +/- 1.5 and 5.2 +/- 1.4 vs. 12 +/- 2.8 cm/s, respectively (p < 0.001). Mean PCWP (20 +/- 8 mm Hg) related weakly to mitral E (r = 0.68) but not to Ea. The E/Ea ratio related well to PCWP (r = 0.87; PCWP = 1.24 [E/Ea] + 1.9), with a difference between Doppler and catheter measurements of 0.1 +/- 3.8 mm Hg. CONCLUSIONS: Ea behaves as a preload-independent index of LV relaxation. Mitral E velocity, corrected for the influence of relaxation (i.e., the E/Ea ratio), relates well to mean PCWP and may be used to estimate LV filling pressures.

Blood Flow Velocity