HYPOTHESIS: Alternating intrathoracic pressure by means of a chest cuirass can cause perfusion and ventilation equal to or better than standard cardiopulmonary resuscitation (CPR) for humans in cardiac arrest. DESIGN: Nonrandomized, nonblinded, crossover pilot study. SETTING: Large urban emergency department. SUBJECTS: Five adult normothermic, nontraumatic, out-of-hospital cardiac arrest patients unresponsive to standard advanced cardiac life support. METHOD: Right atrial and aortic catheters were inserted for pressure measurement and blood gas analysis while the patient was receiving standard CPR by a pneumatic compression device (Thumper). The Thumper was then replaced by a chest cuirass (Hayek Oscillator). Pressure and blood gas measurements were then repeated. RESULTS: The coronary perfusion pressure increased from -1.2 +/- 8.6 mm Hg to 6.2 +/- 6.9 mm Hg for a mean change of 7.4 +/- 3.1 mm Hg (p = 0.006). The compression phase gradient increased 10.0 +/- 21.9 mm Hg (p = 0.364). The venous to arterial PCO2 gradient decreased 44.5 +/- 32.3 mm Hg (p = 0.070). The oxygen extraction ratio increased 1.6 +/- 9.4 percent (p = 0.761). The mean arterial PO2 and PCO2 changed from 252 to 240 mm Hg (p = 0.836) and from 53 to 66 (p = 0.172) mm Hg, respectively. CONCLUSION: The Hayek Oscillator chest cuirass produced a significant improvement in the coronary perfusion pressure. There was a trend for improved systemic perfusion as indicated by an improved compression phase gradient and venous to arterial PCO2 gradient, although this was not supported by the lack of improvement in the oxygen extraction ratio. The cuirass also adequately oxygenates and ventilates unassisted by positive pressure ventilation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H A Smithline, E P Rivers, M Y Rady, H C Blake, R M Nowak. 1994. Biphasic extrathoracic pressure CPR. A human pilot study.. https://doi.org/10.1378/chest.105.3.842

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of ventilation and chest compression performance by bystanders using the Impact Model 730 ventilator and a conventional bag valve with mask in a model of adult cardiopulmonary arrest.

"Bystanders" or lay persons are typically the first caregivers to attend to a victim of out-of-hospital cardiopulmonary arrest. Astronaut crew medical officers (CMO) play a similar role to bystanders aboard the International Space Station (ISS). Studies have demonstrated the importance of bystander cardiopulmonary resuscitation (BCPR) for patient survival before the arrival of emergency medical care. Recent apprehension from bystanders about the threat of contracting communicable diseases during BCPR, however, has led to the consideration of other ventilation systems such as the bag-valve mask (BVM) and automatic transport ventilators (ATV). BVM use is called for during CPR aboard the ISS. This study evaluated the ventilation and compression performance of 40 basic CPR-trained bystanders using either a BVM (adult-sized self-inflating bag with face mask) or an ATV (Model 730 ventilator (M730), Impact Instrumentation, Inc., West Caldwell, NJ). Each two-bystander team gave BCPR to a simulated cardiopulmonary arrest victim using the 2-breath/15-compression cycle for 4 min and then switched roles for another 4-min interval. Compared to BVM use, the M730 led to significantly (p<0.05) lower number of breaths, smaller tidal volumes, airway flows, airway pressures, volume of gas entering the stomach per breath and chest compressions for the 4-min period. The M730 also enabled a bystander to meet the recommendation of 4-breath and compression cycles per minute as per Guidelines 2000. Lastly, ease-of-use scores were significantly higher for the M730 compared to the BVM. Overall, the data suggest that the M730 improves the quality of performance for a bystander performing BCPR.

Cardiopulmonary Resuscitation↗