A fully visualized arthroscopic disc suturing technique.

Abstract

Advanced arthroscopic procedures, including disc suturing, are advantageous in managing temporomandibular joint disorders. These techniques are indicated in cases of long-standing closed lock, displaced discs with reduction, and hypermobility with chronic dislocation. Disc suturing procedures can be done blindly, partially blindly, or fully visualized. Fully visualized suturing techniques have obvious advantages, but can be time-consuming, difficult to perform, and traumatic. This article presents a new suturing technique that is fully visualized and is less time-consuming and relatively easy to perform.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A W Tarro. 1994. A fully visualized arthroscopic disc suturing technique.. https://doi.org/10.1016/0278-2391(94)90438-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fluid pump systems for arthroscopy: a comparison of pressure control versus pressure and flow control.

We set out to compare two pump systems, one in which pressure alone could be controlled and the second in which pressure and flow could be controlled separately. Assessments were carried out by two observers independently. A variety of arthroscopic procedures were studied including arthroscopy of the knee, anterior cruciate ligament reconstruction, arthroscopy and acromioplasty of the shoulder, and arthroscopy of the elbow and ankle. We found that both systems used a similar amount of fluid. However, the operative time was significantly decreased with separate control of pressure and flow. This was related to the fact that there was better visualization and better technical ease with the latter pump. There was significantly less extravasation in the soft tissues. Therefore, based on our assessment, pumps that separately control pressure and flow are significantly better than pumps that control pressure alone. There is distinct advantage in less operative time, greater visualization, technical ease, and less soft tissue extravasation.

Arthroscopes

Indentation instrument for the measurement of cartilage stiffness under arthroscopic control.

Changes in the biomechanical properties of articular cartilage are one of the first signs of the tissue degeneration. We have developed a small size indentation instrument for the quantification of cartilage stiffness under arthroscopic control. During measurement, the indenter imposes a constant deformation on the cartilage and the maximal indenter force, by which the cartilage resists the deformation, is used as a measure for cartilage stiffness. The instrument has been tested in laboratory conditions with elastomer and cadaver knee joint cartilage samples. A linear relationship was found between indenter force and elastomer stiffness (r = 0.990, n = 14) as well as between indenter force and cartilage shear modulus obtained by a reference device (r = 0.879, n = 22). Also, the correlation between two repeated measurements at the measurement sites, used to evaluate the reproducibility, was linear (r = 0.953, n = 16). Quantitative detection of cartilage stiffness is possible with the instrument.

Arthroscopes

Endoscopic carpal tunnel release: a prospective study of complications and surgical experience.

A 63-center prospective study of endoscopic carpal tunnel release using the Agee Carpal Tunnel Release System was conducted in 1049 procedures in 988 patients. Prior experience with endoscopic release varied significantly among surgeon participants. Surgeons evaluated the newly redesigned system for blade visibility, blade height, and mechanical function. Data on patient complications were collected at the time of surgery and 3-4 weeks postoperative. The results indicated minimal complications and no confirmed injuries to vessels or nerves; the symptoms from one possible digital nerve injury eventually resolved completely. Surgeons were able to observe the point of entry of the blade into the transverse carpal ligament in 97.5% of procedures. Introduction of the blade assembly into the carpal tunnel was rated easy or adequate in 90.6% of procedures, and blade height was rated adequate in 97.4% of procedures.

Arthroscopes