PubMed Health⌕ Search

PubMed · 8137069

A new strategy for spectroscopic imaging.

Abstract

This paper describes a new approach for reducing ringing artifacts in spectroscopic imaging (or chemical-shift imaging). The new method is aimed at reducing the signal contamination in areas of interest, due to ringing, that often arises from adjacent areas with high intensity, such as subcutaneous fat in the case of 1H spectroscopy and skeletal muscle in case of the 31P spectroscopy. The method is based on the fact that the high-intensity signals which are the major source of contamination can be captured with one or few acquisitions and the metabolite resonances in areas of interest require considerably more averaging in the data acquisition due to low signal-to-noise ratio. In order to reduce ringing and maintain adequate SNR for the metabolites, the data points in high k space are measured with one or few excitations while those in the low k space are sampled with many excitations. By virtue of this sampling scheme, the data contain more noise in the high-spatial-frequency region and direct Fourier transformation reconstruction generates a very noisy image. Therefore, a new reconstruction technique is developed for the reconstruction. This approach has been studied by simulations and its practical utility is demonstrated by an in vivo proton CSI experiment. Technical details and simulation and experimental results are presented. From these results, it is concluded that the technique is robust and can be used for in vivo applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

X Hu, M Patel, K Uğurbil. 1994. A new strategy for spectroscopic imaging.. https://doi.org/10.1006/jmrb.1994.1004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗