PubMed HealthSearch

PubMed · 8163971

Constrained acetabular components.

Abstract

Between May 1987 and October 1990, 21 constrained acetabular components were used in revision total hip arthroplasty at the University of California, San Francisco. In 18 patients, the device was placed for a chronically dislocating total hip arthroplasty. In the remaining three, intraoperative instability during revision total hip arthroplasty necessitated its use. At the minimum 2-year follow-up evaluation (average, 31 months; range, 24-64 months), 15 patients (71%) experienced no further dislocations or subluxations. There were eight dislocations in the remaining six patients (29%). The average Harris hip score at the follow-up evaluation was 76 points (range, 32-100 points). For those patients who redislocated (n = 6), an increased acetabular abduction angle of the metallic acetabular cup, averaging 70 degrees, was the only predictive factor of failure of the constrained cup (P < .05). No radiographic or clinical evidence of loosening in the 19 porous ingrowth acetabular component was observed. This device will relieve the complication of severe hip instability in the majority of patients, but is not universally successful.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Anderson, W R Murray, H B Skinner. 1994. Constrained acetabular components.. https://doi.org/10.1016/0883-5403(94)90133-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Osteolysis in cemented versus cementless acetabular components.

A prospective, randomized, double-blind, clinical trial comparing cemented with cementless total hip arthroplasty was performed to compare the prevalence and pattern of acetabular osteolysis. Both groups were similar before surgery. Acetabular components were metal-backed, titanium implants. Twenty-eight-millimeter modular femoral heads with titanium femoral stems were used. At a minimum 2-year and mean 4-year follow-up period (range, 2-6 years), 224 patients had clinical and radiographic data available. There was no significant difference in the prevalence of acetabular osteolysis between cemented (5%) and cementless (9%) fixation. With or without cement, the use of a titanium femoral head led to osteolysis within a relatively short period after surgery in almost all of the cases, although this was not significant. The pattern of acetabular osteolysis was different. Progressive osteolysis occurred predominantly in acetabular zone 1 in the cemented group and zone 2 in the cementless group. Cementless fixation of acetabular components has been advocated in an attempt to minimize osteolysis that may occur in cemented total hip arthroplasty. This study found no difference in the prevalence of acetabular osteolysis between the two groups.

Acetabulum

Removal and reinsertion of cemented femoral components during acetabular revision.

A retrospective review examined all patients who underwent removal and reinsertion of a cemented femoral component during isolated acetabular revision by one surgeon since 1981. All components were reinserted into the original, intact cement mantle. Forty-two hips with 2- to 10-year follow-up periods were reviewed. Average follow-up period since revision was 67 months. Average followup period since index procedure was 191 months. Average Harris hip score increased from 61 before surgery to 90 at follow-up examination. Two femurs are definitely loose by Harris criteria, but both are asymptomatic. One solidly fixed femoral component was revised because of joint instability. Two hips have postrevision cement fractures. One patient has mild thigh pain. In vitro testing of eight cadaver hips showed no increase in rotational micromotion following removal and reinsertion. It is concluded that this technique aids in isolated acetabular revision surgery by avoiding the complications of trochanteric osteotomy and femoral revision, improving acetabular exposure, and decreasing operative time with minimal risk of disrupting femoral component fixation.

Acetabulum

The epidemiology of hip osteoarthritis and rheumatoid arthritis in the Orient.

The prevalence of hip osteoarthritis and rheumatoid arthritis has been found to be lower in Chinese, Japanese, and other Asian populations than in whites. The low prevalence of osteoarthritis hip in the Chinese and Japanese populations cannot be explained by the rarity of hip dysplasia, which is as prevalent in those two populations as in whites. As in other populations, rheumatoid arthritis in the Chinese is associated with the shared epitope of the third hypervariable region of the DR gene. However, the low prevalence of rheumatoid arthritis in the Chinese cannot be accounted for entirely by genetic factors.

Acetabulum