PubMed HealthSearch

PubMed · 8189708

Three-dimensional analysis of left ventricular ejection using computational fluid dynamics.

Abstract

We present in this study a method for constructing computational fluid mechanical models in order to study the effects of time-varying left ventricular ejection. A spherical left ventricular model was implemented in which three dimensional flow fields were obtained. The time course of the ventricular wall changes were assumed to have a trigonometrically varying nature. The wall grid was reformed 25 times during the calculation since the left ventricular wall motion was assumed to follow the blood flow, and the ventricle wall radius was reduced by 60 percent in 0.25 seconds. Centerline and cross-sectional velocity vectors greatly increased in magnitude at the aortic outlet, and pressure dropped from 1.17 x 10(4) dynes/cm2 (8.8 mmHg) to zero in the top 10 percent of the heart. The modeling framework will be used with left ventricular cast data coordinates in future studies. There is presently a lack of three-dimensional data based on a realistic model, and the computational method should make it possible to compare simulation results with important measurement techniques such as echocardiography and magnetic resonance imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T W Taylor, H Okino, T Yamaguchi. 1994. Three-dimensional analysis of left ventricular ejection using computational fluid dynamics.. https://doi.org/10.1115/1.2895696

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of anterior communicating artery diameter on cerebral hemodynamics in internal carotid artery disease. A model study.

BACKGROUND: Collateral circulatory pathways are considered the primary determinant of cerebral hemodynamics in patients with obstructive lesions of the internal carotid arteries (ICaAs). However, the hemodynamic effects of the diameter of the anterior communicating artery (ACoA) have never been assessed quantitatively in humans. METHODS AND RESULTS: Two different mathematical models were used to simulate changes affecting blood pressures and flows in cerebral arteries as a function of ACoA diameter and ICaA stenoses or occlusions. Small changes in ACoA diameter were found to have marked hemodynamic effects when they occurred within the range of 0.4 to 1.6 mm, a situation observed in 80% of the cases. Outside this range, changes in ACoA diameter had no effect. Simulated pressure drops through a stenotic ICaA were consistent with those observed. They were found to depend on the degrees of the stenoses in both ICaAs and on ACoA diameter according to a simple equation. Pressure reserve in the middle and anterior cerebral arteries decreased to below the lower limit of autoregulation, despite a normal mean arterial blood pressure, when the arteries were distal to a unique 70% ICaA stenosis associated with a small-diameter ACoA or to a 50% ICaA stenosis associated with a contralateral ICaA occlusion and a large-diameter ACoA. Above these thresholds, the circle of Willis allowed for an almost complete global cerebral blood flow compensation that involved all the afferent and communicating vessels. CONCLUSIONS: ACoA diameter strongly modulates the effects of ICaA lesions on cerebral hemodynamics. Some proposals for endarterectomy indications can be derived from our study.

Blood Flow Velocity