Computing body segment trajectories in the Hybrid III dummy using linear accelerometer data.

Abstract

An analytical method was developed and tested using several mini-sled and Hyge sled tests to calculate the planar trajectory of a Hybrid III dummy head. Aimed at expediting the Hybrid III test analyses, it may provide an opportunity for cost savings through reduced hardware and manpower on film analyses. Transformation from the moving coordinate to the laboratory coordinate is based on the angular positions integrated from the derived angular accelerations. Gravitational correction of the linear accelerometers was found to be insignificant. The computed head trajectories were compared to the ones obtained from the high speed film images. Accuracy of the calculated head trajectory relies heavily on the accuracy of the computed angular acceleration. Strain-gaged accelerometers are not dependable at all times during an impact and an ill-behaved signal for a very short period may create a significant drift in computed displacement due to double integrations. Accuracy of the currently available accelerometers is not high enough for an angular displacement calculation. A new generation of accelerometers with higher accuracy, or an angular velocity sensor may provide more accurate angular displacement for trajectory analyses. The redundancy of the in-line accelerations helps improve the isolation of erroneous outputs and improve accuracy of the procedure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R T Shea, D C Viano. 1994. Computing body segment trajectories in the Hybrid III dummy using linear accelerometer data.. https://doi.org/10.1115/1.2895702

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Minimum energy trajectories of the swing ankle when stepping over obstacles of different heights.

This study was performed to test the hypothesis that the motion of the lower extremities when stepping over obstacles is governed by the criterion of minimum mechanical energy. The trajectories of the swing ankle during level walking and when stepping over obstacles of 51, 102, 153, and 204 mm heights were predicted and measured for eight healthy young adults. The predictions were made with a planar, seven-link linkage model based on the criterion of minimum mechanical energy using the method of dynamic programming. When stepping over obstacles, the predicted trajectories of the swing ankle were just high enough for the swing toe to clear the obstacles. The clearances measured between the obstacle and toe were significantly larger than those predicted. When stepping over obstacles the levels of work required to generate the measured trajectories were significantly larger (p < or = 0.002) than those required to produce the predicted trajectories. The amount of work necessary to generate the measured or predicted trajectories increased linearly (significant at p < or = 0.022) with obstacle height and, except when predicting the trajectory for the lowest obstacle, was significantly greater than that required when walking on level ground (p < 0.02). Thus, conservation of energy was found to become a less dominant criterion for governing the motion of the body when crossing obstacles than when walking on level ground.

Acceleration

A controlled-release ergometer for the human ankle.

A hydraulic ergometer for the human foot is described that can apply ankle rotations up to 1 rad at a constant high speed of 10-20 rad/s against moments up to 200 N m. The initial acceleration is damped, so as not to exceed a preset value. With the presented set-up the series elasticity of the intact human m. triceps surae can be measured.

Acceleration

The upper extremity attenuates intermediate frequency vibrations.

Vibration is related to reports of low back pain; however the biomechanics of vibration transmission through the hand-arm system has not been previously studied. Vibration was recorded on an accelerometer mounted to a pin percutaneously imbedded in the spinous process of L4 of five human subjects. The energy was applied through an impact via a pendulum. The subjects adopted an erect, relaxed or bent knee posture. The first resonance was 4-6 Hz and the second at 9-14 Hz. With the knee bent, the signal was almost completely attenuated. If the impact was applied through a handle and the hand-arm system there was complete attenuation.

Acceleration