Diagnostic algorithm for acute superior vena caval obstruction (SVCO).

Abstract

Acute SVCO presents a serious diagnostic and therapeutic dilemma to the thoracic surgeon. It is highly desirable to obtain a definitive tissue diagnosis but this requirement must be balanced against the risks inherent in invasive diagnostic procedures in these oft-times critically ill patients. In the past 5 years we have developed an algorithm that has been used successfully in 18 patients presenting with acute SVCO. The decision tree consists of scalene node biopsy, bronchoscopy and mediastinoscopy with categorization into low and high risk groups in the latter. The gender distribution of the 18 patients was 12 male and 6 female with the ages being 58.3 +/- 16.3 and 64.2 +/- 11.2 years respectively. The duration of symptoms range from 1.5 to 12 weeks and averaged 4.5 +/- 3.2 weeks. Two patients had palpable scalene nodes which were positive at biopsy. Bronchoscopy was positive in 5 out of 11 examinations. In 5 instances it was not done. Twelve patients underwent various forms of mediastinal biopsy and one underwent sternotomy. Seven patients requiring mediastinoscopy were judged to be high risk as defined by severe airway and vascular obstruction. Perioperative difficulties occurred in two patients due to cardiorespiratory factors associated with the obstruction. Both patients were undergoing cervical mediastinoscopy under general anesthesia and no difficulties were encountered in high risk patients when local anesthesia was used to perform anterior mediastinotomy. Five patients that were considered low risk all underwent uncomplicated procedures under general anesthesia. Thirteen patients proved to have bronchogenic carcinoma and a specific tissue diagnosis was obtained in 12. The undetermined diagnosis was in a patient who had prior radiotherapy.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Bigsby, R Greengrass, H Unruh. 1993. Diagnostic algorithm for acute superior vena caval obstruction (SVCO).. https://pubmed.ncbi.nlm.nih.gov/8227119/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗