Milking machine function and analysis.

Abstract

Milking system evaluation is facilitated by use of a pulsator recorder, airflow meter, and a vacuum stability gauge. The most important points of a milking system are vacuum, inflations, and pulsation. An evaluation sheet for milking systems as proposed by the National Mastitis Council is presented. Paramount to evaluation of any milking system is that the parameters must relate to milking performance or teat and udder health.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J C Dahl, B D Harrington, J A Jarrett. 1993. Milking machine function and analysis.. https://doi.org/10.1016/s0749-0720(15)30619-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Relative humidity under radiant warmers: influence of humidifier and ambient relative humidity.

The effects of humidifier air temperature and flow, and ambient relative humidity (RH(amb)) on RH and air temperature under a radiant warmer (RW) were determined in stable and unstable conditions, using an infant surrogate. Mean supplemented RH under the RW was 36.3% at 14% RH(amb) and 67.6% at 55% RH(amb). Humidifier temperature of 38 degrees C and air flow of 10 LPM produced highest RHs (74.5% and 43.1% in high and low RH(amb), respectively). RH(amb) was highest in summer and lowest in winter in this midwest U.S. hospital, and could be predicted by calendar date (r = 0.58). Humidification equipment capabilities and limitations must be known when using this method to limit evaporative water loss.

Air Movements

Influence of air flow on the behavior of thoron and its progeny in a traditional Japanese house.

Air flow influence on the spatial distribution of thoron (220Rn) concentration in a typical Japanese traditional house was investigated at various indoor air flow levels. The effect of air flow on the behavior of both thoron and radon progeny were examined simultaneously. Measurements were carried out by using two types of passive monitors, the radon-thoron discriminative monitor and the Radtrak monitor. Thoron and radon progeny were measured by filter grab sampling with ZnS scintillation counting. Under static condition, a horizontal distribution with greatly varied thoron concentrations was found as reported by previous studies. Under turbulent conditions, thoron concentrations in the middle of the room increased and the concentration gradient of thoron gas became lower. An obvious vertical distribution of thoron was also observed. Prominent diurnal variation of radon progeny concentrations was observed whereas that of thoron progeny concentrations was not. Concentration of thoron progeny changed little at different air flow levels, although the thoron gas level at the middle of the room varied significantly. The influence of air flows on detection efficiencies of the two types of thoron monitors were also checked. The mechanism of behavioral change of thoron and its progeny in turbulent atmosphere is discussed.

Air Movements

The effect of airflow on site-specific electrical conductance measurements used in the diagnosis of pit and fissure caries in vitro.

There has been renewed interest in the electronic diagnosis of occlusal caries using measurement of conductance or impedance. One of two previously manufactured electronic caries detectors (the Vanguard electronic caries detector, Massachusetts Manufacturing Corporation, Cambridge, Mass., USA) had a probe tip with an integral air supply. Airflow is essential for removing superficial moisture and preventing surface conduction to the gingival margin. The aim of this study was to determine the effect of airflow on electronic diagnosis of occlusal caries using a prototype electronic caries meter (ECM II. LODE, Groningen, The Netherlands) fitted with a flow meter. Stable conductance readings were taken at 76 discrete sites on 32 extracted teeth with no visible signs of cavitation, at 3 airflows: 5, 7.5 and 10 litres/min. The stable conductance scale was a continuous scale from -0.45 to 13.25 and set by the manufacturer. Histological validation was carried out on macroradiographs of sections cut to include each sample site. The histological picture was compared with the stable conductance readings taken at various airflows. Sensitivity and specificity were calculated using different conductance readings to differentiate sound and carious sites, and receiver operating characteristic (ROC) curves constructed. Of the sites, 32% had enamel and dentine caries and 33% had enamel caries. The ROC curves showed airflow to be highly relevant. An airflow of 5 litres/min was shown to be inadequate and led to large numbers of false-positive diagnoses. A minimum airflow of 7.5 litres/min was required to achieve optimum sensitivity (92%) and specificity (87%) for dentine caries diagnosis.

Air Movements