PubMed Health⌕ Search

PubMed · 8251189

Chiral separation using molecularly imprinted heteroaromatic polymers.

Abstract

Novel molecularly imprinted polymer systems utilizing 4-vinylpyridine and 1-vinylimidazole as functional monomers have been developed for enantioselective recognition of carboxylic and N-protected amino acids. Non-covalent interactions between the functional monomers and the template molecules were the source of the subsequent recognition sites in the resultant polymers. The capacity of the polymers for molecular recognition was investigated by using them as stationary phases in the HPLC mode. Polymers prepared with 4-vinylpyridine were found to be more efficient in racemic resolution than those prepared with 1-vinylimidazole. When applying a racemic mixture of the template molecule, the polymers showed highest affinity for the enantiomer used as template. Imprints of a racemic template molecule, as expected, did not exhibit enantioselectivity. The optimal molar ratio of 4-vinylpyridine to the template Cbz-L-Asp-OH in the polymerization mixture was determined to be 12:1. In addition to enantioselectivity, the investigated polymers demonstrated 'ligand selectivity', e.g., a Cbz-L-Asp-OH-imprinted polymer was able to separate Cbz-D,L-Asp-OH, but was unable to separate Cbz-D,L-Glu-OH.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Kempe, L Fischer, K Mosbach. 1993. Chiral separation using molecularly imprinted heteroaromatic polymers.. https://doi.org/10.1002/jmr.300060103

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

HPLC separation and NMR structural elucidation of sn-1,2-, 2,3-, and 1,3-diacylglycerols from olive oil as naphthylethylurethane derivatives.

In this study, sn-1,2-, sn-2,3-, and sn-1,3-diacylglycerols were isolated from olive oil, and their urethane derivatives (urethanes) were prepared. Normal-phase high-performance liquid chromatography (NP-HPLC) separation of the urethane isomers was performed and the separate classes were studied by nuclear magnetic resonance (NMR). The use of 1H NMR and homo- and heteronuclear 2D techniques provided a great amount of information in a very short time, particularly when a high-field NMR instrument (700 MHz) was used. Particularly diagnostic for this kind of compound was the glyceridic moiety that presents typical chemical shifts both for carbon and hydrogen. These studies show the usefulness of NMR spectroscopy to recognize clearly the sn-1,3- and, moreover, sn-1,2- with respect to sn-2,3-diacylglycerols, although very minor differences occur between them.

Chromatography, High Pressure Liquid↗

Solid-phase extraction combined with high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis of pesticides in water: method performance and application in a reconnaissance survey of residues in drinking water in Greater Cairo, Egypt.

Monitoring of water resources for pesticide residues is often needed to ensure that pesticide use does not adversely impact the quality of public water supplies or the environment. In many rural areas and throughout much of the developing world, monitoring is often constrained by lack of testing facilities; thus, collection of samples and shipment to centralized laboratories for analysis is required. The portability, ease of use, and potential to enhance analyte stability make solid-phase extraction (SPE) an attractive technique for handling water samples prior to their shipment. We describe performance of an SPE method targeting a structurally diverse mixture of 25 current-use pesticides and two common degradates in samples of raw and filtered drinking water collected in Greater Cairo, Egypt. SPE was completed in a field laboratory in Egypt, and cartridges were shipped to the United States for elution and high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis. Quantitative and reproducible recovery of 23 of 27 compounds (average = 96%; percent relative standard deviation = 21%) from matrix spikes (1 microg L-1 per component) prepared in the field and from deionized water fortified similarly in the analytical laboratory was obtained. Concurrent analysis of unspiked samples identified four parent compounds and one degradate in drinking water samples. No significant differences were observed between raw and filtered samples. Residue levels in all cases were below drinking water and "harm to aquatic-life" thresholds, indicating that human and ecological risks of pesticide contamination were relatively small; however, the study was limited in scale and scope. Further monitoring is needed to define spatial and temporal variation in residue concentrations. The study has demonstrated the feasibility of performing studies of this type using SPE to extract and preserve samples in the field. The approach should be broadly applicable in many settings.

Chromatography, High Pressure Liquid↗

Retention behavior of oligomeric proanthocyanidins in hydrophilic interaction chromatography.

A novel method was developed for the separation of proanthocyanidins (PAs; oligomeric flavan-3-ols) by hydrophilic interaction chromatography (HILIC) using an amide-silica column eluting with an aqueous acetonitrile mobile phase. The best separation was achieved with a linear gradient elution of acetonitrile-water at ratios of 9:1 to 5:5 (v/v) for 60 min at a flow rate of 1.0 ml/min. Under these HPLC conditions, a mixture of natural oligomeric PAs (from apple) was separated according to degree of polymerization (DP) up to decamers. The DP of each separated oligomer was confirmed by LC/electrospray ionization MS. In further HILIC separation studies of 15 different flavan-3-ol and oligomeric PA (up to pentamer) standards with an isocratic elution of acetonitrile-water (84:16), a high correlation was observed between the logarithm of retention factors (log k) and the number of hydroxyl groups in their structures. The coefficient of this correlation (r2=0.9501) was larger than the coefficient (r2=0.7949) obtained from the correlation between log k and log P(o/w) values. These data reveal that two effects, i.e. hydrogen bonding between the carbamoyl terminal on the column and the hydroxyl group of solute oligomer and hydrophilicity based on the high-order structure of oligomeric PAs, corporately contribute to the separation, but the hydrogen bonding effect is predominant in our HILIC separation mode.

Chromatography, High Pressure Liquid↗