Cervical stability after sequential capsule resection.

Abstract

A portion of the cervical facet joint must be resected to expose and decompress cervical nerve roots from a posterior approach. When posterior fusion is performed, it is common to remove the facet capsule only for the joints being fused. This study was performed to examine the effect of resection of the facet capsule alone, without disruption of the bony facet to determine what degree of facet-capsule resection leads to acute instability. Seven human cervical cadaveric spines were used in the experiment. Nondestructive biomechanical testing was performed in axial load, flexion, extension, and torsion. Each specimen was tested intact and after sequential resection of 25%, 50%, 75%, and 100% of the C5-6 facet capsules. Axial stiffness changed very little during the experiment. In torsion, the displacement increased 1% after a 25% capsule resection, 19% after a 50% resection, and 25% after a 75% or 100% resection. No gross subluxation was seen during the torsional test. In the flexion test, posterior displacement increased 4% after a 25% resection, 5% after a 50% resection, 32% after a 75% resection, and 22% after a 100% resection. There was a statistically increased displacement seen during the flexion test after 75% or 100% of capsule resection. Thus, significant hypermobility did occur during both torsion and flexion testing with greater than 50% resection of the facet capsules. Great care should be taken when exposing an unfused facet to limit facet-capsule resection to less than 50%. With resection of greater than 50% of the capsule, postoperative hypermobility can occur and may require stabilization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T A Zdeblick, J J Abitbol, D N Kunz, R P McCabe, S Garfin. 1993-10-15. Cervical stability after sequential capsule resection.. https://doi.org/10.1097/00007632-199310001-00013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗