PubMed HealthSearch

PubMed · 8288884

ELEASY: a program for processing experimental enzymoimmunoassay data.

Abstract

A computer program is described that automates processing of data from enzyme immunoassays. This includes statistics, data editing, graphic display and fitting of data to both a straight line and a sigmoidal curve. The program can work either without the need for the user to enter choices, initial values, etc., or else with user-controlled choices for adaptation to special data sets.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Herráez. 1993-12-03. ELEASY: a program for processing experimental enzymoimmunoassay data.. https://doi.org/10.1016/0022-1759(93)90373-f

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

siaD PCR ELISA for confirmation and identification of serogroup Y and W135 meningococcal infections.

Non-culture diagnosis and serogroup determination of meningococcal infection is important in contact management where vaccination may be possible. A serogroup B and C PCR ELISA assay for the non-culture diagnosis and serogroup determination has proved invaluable for enhanced epidemiological surveillance and contact management. A polymerase chain reaction assay, based on a restriction fragment length polymorphism in the meningococcal serogroup Y and W135 sialyltransferase (siaD) gene, was developed to enhance the range of non-culture diagnosis of meningococcal infection from clinical samples. The PCR assay was adapted to an ELISA format incorporating hybridisation with serogroup-specific Y and W135 oligonucleotide probes. The serogroup-specific W135 and Y PCR ELISA is a useful addition to currently available serogroup B and C assay for non-culture diagnosis of meningococcal infection and outbreak investigation.

Enzyme-Linked Immunosorbent Assay

Quantification of matrix metalloproteinases and tissue inhibitors of metalloproteinase in prostatic tissue: analytical aspects.

BACKGROUND: The balance between matrix metalloproteinases (MMP) and the tissue inhibitors of metalloproteinases (TIMP) has been seen as important during tumor invasion and progression. The determination of these components needs a special strategy of tissue preparation. This analytical problem has not been considered for prostatic tissue. METHODS: We adapted an extraction method consisting of two extraction steps with 0.25% Triton X-100/CaCl2 solution and two heat extraction steps at 60 degrees C for 4 min. This combination allowed a complete extraction of MMP (measured as enzyme activity) and TIMP-1 (measured with an ELISA test) from cancerous and normal prostatic tissue samples. RESULTS: The median values for cancerous vs. normal MMPs (50.8 mU/g wet tissue and 1,580 mU/g protein vs. 88.8 and 2,497) and TIMP-1 (4.49 micrograms/g wet tissue and 96.7 micrograms/g protein vs. 12.4 and 237.8) were significantly lower, whereas the respective ratios for MMP/ TIMP-1 (11.1 vs. 4.0 on wet weight and 15.5 vs. 5.3 on protein basis) were significantly higher. CONCLUSIONS: An optimized extraction procedure was elaborated for determining MMPs and TIMP-1 in prostatic tissue samples. The increased ratio of MMP/TIMP-1 can be interpreted as an indicator of the imbalance between MMP and TIMP, characteristic of prostate carcinoma tissue.

Enzyme-Linked Immunosorbent Assay

Development of an immunoassay specific for the PSA-ACT complex without the problem of high background.

We have developed an assay specific for the PSA-ACT (PSA-alpha 1-antichymotrypsin) complex that effectively diminishes the problem of high assay background commonly reported by other investigators. The assay follows a two-site ELISA format. Polyclonal anti-PSA antibodies were coated on the microplate to capture the PSA complex from the serum, whereas the biotinylated anti-ACT polyclonal antibodies and HRP-conjugated streptavidin were used for detection. The high background ordinarily associated with this assay was greatly reduced when milk casein was added in addition to albumin for blocking and when the Super Block was also included in the diluents for sample dilution and dilution of enzyme conjugated detecting antibodies. The assay has a sensitivity of 0.05 ng/mL. The within-run precision ranges from 4.2-7.2% and the between-run precision falls between 5.8-8.5%. Cross reactions with ACT and free PSA (fPSA) are 0.0001% and 0.02%, respectively. The highest concentration of PSA-ACT complex in the maternal sera was < 0.4 ng/mL by this assay, much less than reported in the literature. Using this improved assay, the sum of fPSA and PSA-ACT concentrations were less than that of their corresponding total PSA (tPSA) most of the time. We believe that this improved assay should be used to replace the current tPSA assay for screening, monitoring, and managing patients with prostate cancer.

Enzyme-Linked Immunosorbent Assay