PubMed HealthSearch

PubMed · 8296558

[Neonatal hearing screening].

Abstract

Auditory deprivation in early life significantly effects speech, language, cognition and learning development. The importance of neonatal hearing screening in order to detect and manage children with hearing impairment during the critical period before three years of age can't be neglected. The neonatal hearing screening program at Veterans General Hospital, Taipei, under a cooperation of audiologists, otologists and pediatricians, identified 1885 neonates for hearing loss from September 1990 to August 1991. There were two study groups, a high risk group of hearing impairment and a non-high risk group. We performed hearing screening and followed-up for the failure at initial test using methods including behavioral observation audiometry, auditory brainstem response, tympanogram, pneumatic otoscopy and questionnaire. Approximately 2.7% of neonates were classified as high risk for hearing loss, the incidence of hearing loss was 8% to 14% in this group. The incidence of hearing loss in non-high risk group was 0.11%. If both groups were contained that the incidence of hearing loss was 0.32% to 0.48%, 0.11% with a sensorineural hearing loss, 0.21% to 0.37% with a conductive hearing loss. Both behavioral audiometry (89% false negative rate) and questionnaire (50% return rate) were not effective for screening purposes in this study. Our results also indicated that the most advantage of using a high risk register lay in the fact that only 2.7% of a total population needed to be screened to identify approximately 67% to 78% of hearing-impaired babies. This saved both time and money.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M L Kuan, C F Lien, S J Chen, P Chang. [Neonatal hearing screening].. https://pubmed.ncbi.nlm.nih.gov/8296558/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Otologic manifestations of Wolf-Hirschhorn syndrome.

OBJECTIVE: To determine if haploinsufficiency for chromosome 4p16.3 in Wolf-Hirschhorn syndrome (WHS) is associated with cochlear hearing loss. DESIGN: Case series. SETTING: Tertiary care center. PATIENTS: Six patients with WHS were identified through a database and charts were retrospectively reviewed. MAIN OUTCOME MEASURES: Presence of sensorineural hearing loss as assessed by brainstem auditory evoked response. RESULTS: One of the 6 patients had sensorineural hearing loss. Three of the 6 patients had chronic otitis media with effusion and underwent bilateral tympanostomy tube placement; 2 of these 3 had cleft lip and palate, and 1 had a bifid uvula. One of the 6 patients had spontaneous nystagmus. Five of the 6 patients had preauricular and/or auricular abnormalities. CONCLUSIONS: More than 25 genes for nonsyndromic hereditary hearing impairment have been mapped. One of these genes, DFNA6, was identified through linkage analysis of a family with dominant, progressive, low-frequency sensorineural hearing loss. DFNA6 maps to chromosome 4p16.3, a region that is partially deleted in patients with WHS. In our series, we identified the second patient with WHS in the literature with bilateral sensorineural hearing loss. The incidence and type of otologic findings are consistent with those reported in the literature. Analysis of patients with chromosomal rearrangements represents one strategy toward identifying candidate genes for genetic hearing impairment.

Audiometry, Evoked Response

Reversing click polarity may uncover auditory neuropathy in infants.

OBJECTIVE: To identify patients with primary auditory neuropathies whose cochlear potentials to a 100 microsec click persist after click cessation and simulate synchronous auditory brain stem responses (ABRs) at high intensities. DESIGN: ABRs to condensation and rarefaction clicks, as well as Maximum Length Sequence ABRs and one transtympanic electrocochleogram (ECochG), were collected from five infants with absent middle ear muscle reflexes and normal or near normal otoacoustic emissions. These infants failed ALGO screens, which used alternating polarity clicks, and/or failed full ABRs done elsewhere with alternating polarity clicks. RESULTS: When ABRs were collected in response to a single polarity pulse, they revealed robust and reproducible wave forms over 4 to 6 msec that initially were mistaken for a normal ABR by the referring agents. However, when condensation and rarefaction click data are compared, the waveforms change polarity when the stimulus is inverted. Furthermore, the waveforms fail to shift in latency as the intensity of the stimulation is reduced. Transtympanic ECochG on one of the children revealed the same polarity reversal and fixed latency functions, confirming that they were cochlear rather than neural responses. CONCLUSIONS: Comparing responses with positive versus negative polarity clicks may help separate ABRs from cochlear potentials and alert clinicians to the possibility of an auditory neuropathy. Therefore, absent or abnormal ABRs in the presence of normal otoacoustic emissions need not always implicate a purely "central disorder," but might be consistent with dysfunction between outer hair cells and primary afferent fibers.

Audiometry, Evoked Response

Newborn hearing screening: the great omission.

OBJECTIVE: The advent of technologic improvements in assessing the hearing of newborn infants has made possible the implementation of universal newborn hearing screening. Furthermore, selective screening based on high-risk criteria fails to detect half of all infants with congenital hearing loss. Although universal screening has been recommended by the National Institutes of Health and the Joint Committee on Infant Hearing Screening, data to support this recommendation have been incomplete, and the recommendation has been seen as without solid foundation by many in the pediatrics field. This study was designed to assess the feasibility, accuracy, and cost-effectiveness of a hospital-based hearing screening program for all newborns. METHODOLOGY: Between 1992 and 1996, hospitals in Colorado with 100 or more births per year were targeted to participate in universal hearing screening of newborns. To date, 26 of 52 targeted hospitals, ranging in size from 40 to 3500 births per year, have implemented universal screening. A total of 41 796 infants were screened between 1992 and 1996. Screening was performed using automated auditory brainstem response, otoacoustic emission testing, or conventional auditory brainstem response, with follow-up testing performed on those infants who failed initial screening. RESULTS: Of 41 796 infants screened at birth, 2709 failed initial screening, and of 1296 who have completed reevaluation, 94 have been identified with congenital sensorineural hearing loss (75 bilateral) and an additional 32 identified with conductive hearing loss (14 bilateral). The frequency of bilateral congenital hearing loss requiring amplification therefore is shown to be at least 1 in every 500 newborns. During the study period, an additional 17 children with significant hearing loss not identified until >/=18 months of age were reported voluntarily; all 17 had been born at hospitals not participating in newborn hearing screening. The false-positive rate for the screening program to date in Colorado is calculated to be 6%, but evolving technology has resulted in improvements to as low as 2%. Positive predictive value of an abnormal screen result is shown to be at least 5%, and as high as 19%, with improving technology. The sensitivity of newborn screening is demonstrated to be at or near 100%. Costs of screening are compared with other screened congenital diseases; although the true cost per child for newborn hearing screening is significantly higher than screening tests performed on blood, the much higher incidence of congenital hearing loss results in a comparable cost per case diagnosed when compared with hypothyroidism or phenylketonuria, for example. The feasibility of early intervention is demonstrated, with amplification by the use of hearing aids being the catalyst for effective treatment. Finally, the costs of screening and early intervention are compared with the monetary savings in avoiding delayed and therefore intensive therapy and intervention for children not diagnosed at birth. The true cost of screening for one newborn is shown to be between $18 and $33, with an average cost of $25 per infant. The cost per case of congenital hearing loss diagnosed is approximately $9600. A model for cost predictions and subsequent intervention savings is presented, and recovery of all screening costs is demonstrated after only 10 years of universal screening in Colorado. CONCLUSIONS: Universal newborn hearing screening is feasible, beneficial, and justified, as indicated by the frequency of the disease, the accuracy of screening tests, the ability to provide early intervention, the improved outcomes attributable to early amplification, and the recovery of all screening costs in the prevention of future intervention costs. Furthermore, the incidence of bilateral congenital hearing loss is alarming, and is, in fact, many times greater than the combined incidence of all newborn screening tests currently performed on blood samples.

Audiometry, Evoked Response