Abstract

With the current emphasis in healthcare delivery on patient outcomes and quality care, infusion therapy nurses and managers must use effective quality improvement processes. This article reviews the terminology associated with the quality improvement processes, provides a brief overview of methods for identification of "quality improvement areas" in infusion therapy activities, and offers monitoring examples for those who are evaluating quality care delivery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B S Gaines. Quality improvement processes applied to infusion nursing practice.. https://pubmed.ncbi.nlm.nih.gov/8301404/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The bag method for islet cell infusion.

As islet cell transplantation gains increasing interest following results published by the Edmonton group, results that have been successfully reproduced by several centers nationwide and abroad, the need of guidelines to standardize the procedure becomes highly important. We detail the key steps of the infusion procedure utilizing a closed gravity fed bag system utilized at our institution since 1990, which consists of a 600-ml transfer bag and a 150-ml rinse bag connected via sterile tubing. The use of gravity allows for a control rate of infusion as well as providing a safety mechanism through natural reduction of flow that parallels any increase in portal pressure, therefore allowing the operator to prevent precipitous pressure rises. Reports on significant rise in portal pressures during islet cell infusion as well as portal vein thrombosis have been published. Infusion at these centers was carried out using a syringe method. Using our technique, portal vein thrombosis (partial or complete) was not detected in any of the infusions performed at our institution. This method may be of assistance to minimize some of the observed complications associated with islet transplant procedures and has now been adapted by most centers performing clinical islet transplantation.

Infusions, Intravenous↗

A method for estimating the delivery temperature of intravenous fluids.

Despite rigorous efforts to monitor and control the fluid temperature within a warmer, the actual delivery temperatures of intravenous (i.v.) fluids at a patient infusion site are not assessed in current clinical practice. A method which correlates the warmer temperature with the delivery temperature will provide the appropriate quality assurance framework. For fluids administered through typical 0.260- and 0.300-cm-diameter polyvinyl chloride (PVC) i.v. tubing, we developed such a method by directly measuring the delivery temperatures for saline, 6% hydroxyethyl starch (HES), 5% albumin, plasma, and packed red cells (PRC) using intratubing thermocouple wire probes. A kinetic analysis of the data yielded the following relationship governing temperature equilibration for fluids in i.v. tubing: f = L/(24 Q + L), where f represents the equilibration fraction, L the tubing length (cm), and Q the flow rate (mL/min). The equilibration fraction f is defined as (Ti - Td)/(Ti - Ta), where Ti, Td, and Ta represent the initial fluid temperature, the delivery temperature, and the ambient air temperature in centigrade, respectively. Both the fluid type and the variability in tubing construction had negligible effects on the delivery temperature. Under given conditions of Q and L, the relationship enables the calculation of the temperature equilibration fraction f and, subsequently, the delivery temperature. Furthermore, the i.v. tubing length or the particular L/Q may be calculated for a desired target temperature and the corresponding f. We conclude that, despite many complicating variables, one can effectively assess and even control the delivery temperature of i.v. fluids administered through typical i.v. tubing.(ABSTRACT TRUNCATED AT 250 WORDS)

Infusions, Intravenous↗

Steady-state volume of distribution and dilution factor.

In 1919 Widmark published in Sweden a paper about the elimination of ethanol and acetone from blood introducing the concept of volume of distribution. The ratio between the total amount of drug in the body (Q(t)) and its concentration in the plasma (C(t)), usually the only site accessible to sampling, shall be called 'apparent volume of distribution'. The ratio changes with time, because Q(t) depends on the elimination and C(t) depends on both elimination and distribution. Therefore the apparent volume of distribution varies between the 'initial volume' and the 'steady-state volume'. The former is defined as the ratio between the dose D given as a bolus at time t = 0 and the value of C(t) extrapolated at t-->0 ignoring the values of the concentration taken before the drug is uniformly mixed in the plasma; the initial volume is obviously equal to plasma volume. The steady-state volume is defined as the value of the ratio between Q(t) and C(t) extrapolated at t-->infinity. Now a new parameter is introduced, called 'dilution factor' and defined as the value of the ratio between the total amount of drug in the body (Q(t)) and the amount of drug in the plasma (X1(t)) extrapolated at t-->infinity. However the ratio between X1(t) and the initial volume is equal to C(t), then the dilution factor is also equal to the ratio between the steady-state volume and the initial volume.(ABSTRACT TRUNCATED AT 250 WORDS)