PubMed Health⌕ Search

PubMed · 8302043

Spinal biomechanics.

Abstract

The lumbar spine is a source of disability due to low back pain (LBP), yet the precise diagnosis is unknown in 80-90 percent of patients. The lifetime prevalence is 75 percent with a cost to the U.S. economy as high as 80 billion dollars. The problem is partly caused by mechanical overloading of the tissues and thus, there is some potential for both primary and secondary prevention. Biomechanical techniques have been effective in improving our understanding of the loading conditions leading to LBP, and in developing techniques for improved diagnosis and more effectual methods of treatment. Much progress has been made through the use of biomechanical models. Most models assume that the external moments are balanced by trunk musculature. Multiple muscle system models, employing agonist and antagonists, now are available to define 3D spine reaction forces. The static indeterminacy is taken care of either by simplification of the model or by linear or nonlinear optimization. Dynamic analysis has shown that vibrational and impact conditions (such as vehicle driving) can excite the natural frequency of the spine and lead to high spinal loadings. In vivo measurements have shown the resonant frequency of the lumbar spine to be 4-5 Hz and many vehicles excite those frequencies. New biomechanical techniques employing electromyography can estimate muscle load and muscle fatigue. Stereo photogrammetric techniques for establishing segmental kinematics have great potential for improving the diagnosis of spinal problems. These techniques are solidly based on prior in-vitro measurements of spinal kinematics. Mechanical fixation techniques, such as pedicle fixation, show great promise in improving the treatment of spinal problems. These have been extensively analyzed by both finite element techniques and in-vitro simulation so as to improve design as well as surgical technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Pope, J E Novotny. 1993. Spinal biomechanics.. https://doi.org/10.1115/1.2895542

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗