Abstract

An exciting application of using Selective Laser Sintering (SLS) to produce solid models of microscopic specimens imaged with a laser scanning confocal microscope is presented. The SLS model, fabricated by sintering together successive layers of a fine powder with a computer controlled scanning laser, is a true 3-D magnification of the microscopic sample. The 3-D models produced are accurate representations of the data and can be handled and manipulated to evaluate surface details and morphology. The models give an extremely powerful method for 3-D data visualization and tactilization. Three dimensional digital image processing is performed on microscopic images to prepare the data for the selective laser sintering process. The image processing techniques for preparing 3-D images of both translucent and opaque specimens for laser sintering are presented. For translucent specimens, the image processing removes noise and "fills in" inclusions and cavities within the specimen data in order to produce a structurally sound model. When imaging an opaque specimen an image of the upper surface alone is acquired. Image processing is used to remove noise and to Fill the volume under the specimen surface. Sample models of a dandelion (Taraxicum officinale Compositae) pollen grain and the surface of a U.S. penny are presented. These models present examples of both the translucent and opaque data types.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K A Bartels, A C Bovik, R C Crawford, K R Diller, S J Aggarwal. 1993. Selective laser sintering for the creation of solid models from 3D microscopic images.. https://pubmed.ncbi.nlm.nih.gov/8329596/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid and accurate measurement for phase-change optical recording bits.

Conducting atomic force microscopy (CAFM) and scanning surface potential microscopy (SSPM) have been used to image the phase-change optical recording bits. Commercially available digital versatile discs (DVD) + rewritable (RW) with initialization process were measured in experiments. Comparing the measurement results of both, the measurement resolution of CAFM is far superior to that of SSPM. With the DVD + RW disc rotating at a linear speed of 3.5 m/s, appropriate writing laser power range, may be precisely identified by CAFM as 10-15 mW. This is sufficient to verify the high-resolution recording bits research method. This new method may also be applied to the development of new types of phase-change recording materials.

Image Processing, Computer-Assisted↗

Image analysis by pulse coupled neural networks (PCNN)--a novel approach in granule size characterization.

A biologically inspired spiking neural network model, the pulse coupled neural network (PCNN), has been applied for the first time in bulk particle characterization, and specifically in the characterization of pharmaceutical granule size distributions. The PCNN was trained on surface images of pharmaceutical granule beds, and the adjustable parameters (radius neuron interconnection, r0, linking weight coefficient, beta, local threshold potential, VTheta, and number of iterations) were successfully optimized using design of experiments. As demonstrated with size fractions of granules, it was found that the PCNN produced granule size-dependent signals. In general, a first highest and relatively narrow peak located in the region of two to twelve iterations corresponded to smaller particle size, while larger particles resulted in wider peaks and in highest (not first) peak at a range between 13 and 25 iterations. Better predictions, i.e. lower RMSEP (root mean squared error of prediction) values, were obtained using high beta value, low r0 and VTheta values, while the number of iterations had to exceed 110 and the optimized model (RMSEP lower than 5) corresponded to PCNN variables: r0=1, beta=0.4, VTheta=2, and number of iterations=150. The coefficient of determination (R2) of the model was 0.94 and the predicted variation (Q2) was 0.91, while the Pearson correlation coefficient between the predicted and the measured mean particle size by sieving for eight test batches was 0.98. These findings could be characterized as promising and encouraging for the further use of image analysis by PCNNs in pharmaceutical bulk particle size and shape characterization.

Image Processing, Computer-Assisted↗

Production of siRNA- and cDNA-transfected cell arrays on noncoated chambered coverglass for high-content screening microscopy in living cells.

In this chapter, we provide a protocol for the production of transfected cell arrays in living mammalian cells on noncoated chambered coverglass for the systematic functional analyses of human genes by high-content screening microscopy. This method should facilitate drug target validation by small-interfering RNAs.

Image Processing, Computer-Assisted↗