PubMed · 8330913
Aspiration liver biopsy.
Abstract
BACKGROUND: Traditional and disposable liver biopsy needles are expensive and add to economic burden in developing countries where the prevalence of liver disease requiring liver biopsy is high. AIM: To compare the technique of suction aspiration using a disposable syringe and an ordinary 40 mm long 18 gauge needle (internal diameter 1.27 mm), with Vim-Silverman's needle in obtaining liver tissue in patients with liver disease of various etiology. METHODS: Liver biopsy was performed in 60 patients each using either technique. The size of the biopsy tissue obtained and the number of times a diagnosis was reached with the two techniques were compared. RESULTS: The mean size of tissue obtained by suction aspiration (11.2 mm) was greater than that by the Vim-Silverman technique (6.3 mm) (p = 0.001). The tissue sample was inadequate for opinion in 3 patients in the aspiration group and in 10 patients in the Vim-Silverman group (p = ns). CONCLUSION: Suction aspiration liver biopsy can be done satisfactorily using disposable syringe and 18 gauge needle.