A personal dosimeter prototype for static magnetic fields.

Abstract

A personal dosimeter prototype, for static magnetic fields with three Hall probes, has been designed and built to provide a reliable instrument for long-term analysis. The probe output signals, proportional to the magnetic flux density components of the vector B, are filtered, sampled, and stored in a buffer memory sufficient to cover a whole worker shift. The data sampling rate is high enough to record the operator movements within the fringes of the magnetic field. The content of the buffer memory is then transferred on a personal computer and registered on individual dosimetric cards. The data can be used for personal exposure monitoring.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Cavagnetto, P Prati, V Ariola, P Corvisiero, M Marinelli, A Pilot, G Taccini. 1993. A personal dosimeter prototype for static magnetic fields.. https://doi.org/10.1097/00004032-199308000-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

EMF statement.

Explore the source record for details and available documents.

Electromagnetic Fields

Induced current and SAR distributions for a worker model exposed to an RF dielectric heater under simulated workplace conditions.

We have used the finite-difference time-domain method to calculate the distributions of absorbed energy for a 1.34 x 1.34 x 1.4 cm resolution anatomically based model of the human body for exposure to leakage electromagnetic fields of a radiofrequency dielectric heater operating at 40.68 MHz. To simulate workplace conditions, the dielectric heater is assumed to be placed in a screen room and different operator postures, such as standing or sitting on a wooden or metal stool with hands on sides or extended toward the radiofrequency heater, are considered. To obviate the problem of having to model a fairly large volume of the screen room of assumed dimensions 2.13 x 3.05 x 2.13 m, we have used a uniform finer grid of points for the finite-difference time-domain method for the closely coupled region consisting of the front region of the heater and the human model, while a newly developed expanding-grid finite-difference time-domain formulation is used elsewhere. This results in a saving of both the memory and computation times by almost a factor of four. The average rates of energy absorption are given for the whole body, selected parts of the body, and various organs. As expected, the foot currents and the rates of energy absorption are higher with the screen room for sitting postures where the upper parts of the body are in higher electromagnetic fields, and for hands extended toward the heater.

Electromagnetic Fields

Regulation of c-fos is affected by electromagnetic fields.

The goal of the present study was to determine if regulatory regions of the c-fos gene were responsive to electromagnetic field exposure. The research design used transfected cells to increase the sensitivity of assays designed to identify changes following exposure. HeLa cells were transiently transfected with plasmids containing upstream regulating regions of c-fos up to -700 base pairs, coupled with the prokaryotic reporter gene CAT. Cells were exposed to an environmentally relevant EMF of 60 Hz at 60 mGrms. CAT expression above control levels in transfected cells (region +42 to -700 bp) was observed following 5 min exposure to the electromagnetic field, with a peak at 20 min. The expression was at basal levels following 40 min exposure. Deletion analysis of upstream DNA narrowed the responsive region to 138 base pairs from -363 to -225, which contains the SRE/AP-1 sites.

Electromagnetic Fields