Choosing a powerful lithotriptor.

Abstract

Clinicians have no yardstick to help them choose the most efficient lithotriptor. Their leading priority is a system allowing complete disintegration of the stone with the minimum number of shocks and a low re-treatment rate. One of the prerequisites of this system is a powerful shock wave generator. "Power" is as yet ill defined in lithotripsy. Therefore clinicians' choice depends upon other factors. Acoustic output measurements were recorded on 3 commercial lithotriptors representing the 3 main shock wave generating systems. These were the Dornier MPL 9000 (standard and X-155 electrodes), the Siemens (Lithostar, Lithostar Plus and System C) and the Wolf Piezolith 2300. The shock wave measurements were correlated to the capability of the lithotriptors to disintegrate standard stone models in vitro. Two factors were identified. The pulse intensity integral in the focus and the size of the focal zone proved to be the most important factors to assess and compare the efficacy or "power" of different lithotriptors. Together they can help clinicians to identify and choose the most efficient shock wave generating systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S F Mishriki, N P Cohen, A C Baker, M I Wills, H N Whitfield, R C Feneley. 1993. Choosing a powerful lithotriptor.. https://doi.org/10.1111/j.1464-410x.1993.tb16059.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acoustic noise reduction in a 4 T MRI scanner.

High-field, high-speed magnetic resonance imaging (MRI) can generate high levels of noise. There is ongoing concern in the medical and imaging research communities regarding the detrimental effects of high acoustic levels on auditory function, patient anxiety, verbal communication between patients and health care workers and ultimately MR image quality. In order to effectively suppress the noise levels inside MRI scanners, the sound field needs to be accurately measured and characterized. This paper presents the results of measurements of the sound radiation from a gradient coil cylinder within a 4 T MRI scanner under a variety of conditions. These measurement results show: (1) that noise levels can be significantly reduced through the use of an appropriately designed passive acoustic liner; and (2) the true noise levels that are experienced by patients during echo planar imaging.

Acoustics↗

Evaluation of a photoacoustic detector for water vapor measurements under simulated tropospheric/lower stratospheric conditions.

Although water vapor is one of the most important and certainly the most variable minor constituent of the atmosphere, accurate measurements of p(H20) with high time resolution are difficult, particularly in the cold upper troposphere/lower stratosphere. This work demonstrates that a diode laser-based photoacoustic (PA) water vapor detector is a viable alternative to current water vapor sensors for airborne measurements. The PA system was compared with a high-quality frost point hygrometer (FPH) and with a Lyman-alpha hygrometer in the pressure range of 1000-100 hPa at frost point temperatures between 202 and 216 K. These conditions were simulated in a large environmental chamberfor 14 h. Simultaneous measurements with the three instruments agreed within 6%. Nitric acid vapor interferes with the FPH measurements at low frost point temperatures but does not affect the other instruments. The sensitivity of the PA system is already sufficient for measurements in the upper troposphere, and straightforward improvements can extend its useful range above the tropopause. Rugged construction, extreme simplicity, small size, and potential for long-term automatic operation make the PA system potentially suitable for airborne measurements.

Acoustics↗