Intraaortic balloon entrapment.

Abstract

A review of intraaortic balloon pump use at the University of Miami/Jackson Memorial Medical Center over the past 21 years identified 2 cases where a balloon was found to be entrapped. The balloon catheters had been in place for approximately 10 days when this complication occurred. The retained balloons were torn, filled with clotted blood, and impacted in the vasculature. In our first case, forceful removal of the intraaortic balloon was complicated by unintentional extraction of the external iliac and common femoral arteries. In the second case, clot within the balloon was dissolved with tissue plasminogen activator injected into the drive lumen of the catheter before removal. The prevention and management of this rare but serious complication of intraaortic balloon pumping is reviewed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M D Horowitz, M Otero, E J de Marchena, R M Neibart, S Novak, H Bolooki. 1993. Intraaortic balloon entrapment.. https://doi.org/10.1016/0003-4975(93)91180-u

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tip cooling effect and failure mechanism of field-emitting carbon nanotubes.

The cooling effect accompanying field electron emission has been considered for a single carbon nanotube (CNT) used as a field emission (FE) electron source. An improved model for the failure mechanism of field emitting CNTs has been proposed and validated. Our model predicts a maximum temperature (T-max) located at an interior point rather than the tip of the CNTs, and the failure of the CNT emitters tends to take place at the T-max point, inducing a segment by segment breakdown process. A combination of Joule heating and electrostatic force effect is proposed responsible for initiating the failure of the field emitting CNT and validated by in situ FE observation.

Equipment Failure↗

[Importance of an initial check-up for diagnostic radiology apparatus management].

The management of apparatus for diagnostic imaging is an important job for radiological technologists. In the last 10 years we have encountered 2227 malfunctions in 3652 days. We detected 163 cases at the initial check-up, which accounted for 7.3% of total cases. By performing an initial check-up, we detected one malfunction every 21 days and were able to keep the effects of mishaps to a minimum, prevent accidents, and obtain stable-quality images.

Equipment Failure↗