[Hardware].

Abstract

For effective management of clinical laboratory in spite of a shortage of medical technologists, we modified conventional analytical instruments on the market, and developed the automatic transport mechanism and the robotic analytical instruments to suit the operational needs of our laboratory. Consequently, we succeeded in designing a system in which the results for 89% of all the tests ordered were reported within 60 minutes after the time when the specimens were received at the laboratory. As a result of this laboratory automation system, medical technologists were spared from their routine work, and their expertise was now diverted to the other duties like examination for microbes in hospital facilities, evaluation for sterilization of surgical instruments, and maintenance of measuring apparatuses in the operating rooms. In addition, the technologists also became involved in preventive health activities for university personnel such as: periodical healthy check, and screening programs for adult diseases, and the like. Some became engaged in the health management programs for radiological department workers. Thus, the introduction of this laboratory automation system, enabled the medical technologists to cooperate in hospital operation activities and to contribute to the prevention of iatrogenic disorders.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Sasaki. 1993. [Hardware].. https://pubmed.ncbi.nlm.nih.gov/8350506/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Combining QUANTICYT karyometric analysis with architectural confocal-aided cytology to prognosticate superficial bladder cancer.

For this study, bladder washings of 923 patients with a follow-up for superficial bladder cancer were used. For the prognostication of each case (follow-up period up to 20 mo), two parameters were used: tumor recurrence and the event of (progressing) invasive growth. Each sample was classified as negative, low grade or high grade, based on confocal-aided architectural cytology. The feature architecture was based on the images of the epithelial fragments as seen in the Feulgen stain, which also could be visualized in confocal microscopy. The same three classes were also used for grading the samples according to the QUANTICYT system, in which DNA and morphometry of nuclei were automatically assessed. The 532 cases graded as QUANTICYT high had a worse prognosis than the 391 cases with QUANTICYT low. In addition, architectural cytology contributed significantly for the prognostication of cases classified as QUANTICYT high, the 228 nonconcording cases faring better than the 304 concording ones. For QUANTICYT low, the 156 nonconcording cases had also a lower recurrence rate than the 235 concording ones, but this difference was only significant in patients followed for up to 8 mo. These findings indicate that QUANTICYT grading supplemented by architectural cytology supplies the clinician with valuable prognostic information which can be used to limit cystoscopies.

Automation

Automation in cytology: a survey conducted by the New Technology Task Force, Papanicolaou Society of Cytopathology.

Despite the overwhelming interest in the development of several computer based technologies in the last several years, the role of automation in cytology has remained controversial. The potential of these technologies in the reduction of false negative results in pap smears is well recognized. However, there is still remarkable confusion as how to incorporate automation in the routine practice of cytology. This prompted the New Technology Task Force of the George Papanicolaou Society of Cytopathology to design a survey to seek the opinion of those engaged in cervicovaginal cytology screening regarding the value of automation in cytology. In 1996, a ten question survey was sent to 1800 cytopathology laboratories throughout the nation. The response rate was 23% (416/1800). The responders represented laboratories varying from those with less than 5,000 pap smears to those with over 100,000 cases per year. The majority of the responders did not believe that automation is essential for cervicovaginal cytology. This was evidenced by the fact that only 12% of the laboratories were engaged in automated cytology and predominantly used it for quality control measures. The inability of small laboratories to absorb the extra expense involved in the integration of automated cytology in their practice, particularly in the current era of managed care was a major concern. There was also concern about the potential for compromise of patient care by the drive for corporate profits and the dissemination of wrong information to the public and physicians. Suggestions most frequently proposed included appropriate patient and physician education about the merits and pitfalls of the pap smear, and also endorsing an affordable universal fee for pap smears. Rescreening for all pap smears, reassessing the benefits of automation in cytology and development of the standards were other proposals. Partnership with larger cytology laboratories, creation of "cytology consortiums" with shared resources to provide regionalized automated rescreening services were also strongly suggested. This survey clearly indicates the need for further evaluation of automation in cytopathology and a focused attention to various issues surrounding cervicovaginal cytology screening.

Automation

Design, construction and six years' experience of an integrated system for automated handling of discrete blood samples.

The present paper describes the design of an integrated system to aid in the taking and measurement of manual blood samples during nuclear medical examinations requiring blood sampling. In contrast to previously published systems, the present system is not used in the actual sampling of the blood, but aims to aid in all other aspects of handling and measurement. It consists of two main parts. One part is a distributed software system running on the scanner host computer used to register sample times, to display information pertaining to the ongoing examination and to collect data from a number of well crystals. The other main part consists of an industrial robot used to perform the actual weighing, centrifugation, pipetting and measurement of the samples. The system has been operational for 6 years, during which time it has had an "up-time" in excess of 95% and has handled and measured the blood samples from more than 5000 examinations, each comprising an average of 15 blood samples. The throughput of the system is 50 whole blood samples or 21 plasma samples per hour. In addition it has to a large extent removed the "human factor" from the process, thereby increasing the reliability of the data.

Automation