PubMed HealthSearch

PubMed · 8350568

[Dear midwives].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Kolehmainen. 1993. [Dear midwives].. https://pubmed.ncbi.nlm.nih.gov/8350568/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A dynamic phantom for radionuclide renography.

The aim of the study was to develop and test a dynamic phantom simulating radionuclide renography. The phantom consisted of five partly lead covered plastic containers simulating kidneys, heart, bladder and background (soft tissues, liver and spleen). Dynamics were performed with multiple movable steel plates between containers and a gamma camera. Control of the plates is performed manually with a stopwatch following exact time schedules. The containers were filled with activities (99mTc) which produce count rates close to clinical situations. Count rates produced by the phantom were compared with ten clinical renography cases: five 99mTc MAG3 and five 99mTc DTPA examinations. Two phantom simulations were repeated three times with separate fillings, acquisitions and analyses. Precision errors as a coefficient of variation (CV) of repeated measurements were calculated and theoretical values were compared with the corresponding measured ones. A multicentre comparison was made between 19 nuclear medicine laboratories and three clinical cases were simulated with the phantom. Correlations between count rates produced by the phantom and clinical studies were r = 0.964 for 99mTc MAG3 (p < 0.001) and 0.961 for 99mTc DTPA (p < 0.001). The precision error was 4.5 +/- 3.2% and the percentage difference between theoretical and measured values for Tmax was 4.0 +/- 1.6%. Images and curves of the scanned phantom were close to a real patient in all 19 laboratories but calculated parameters varied: the difference between theoretical and measured values for Tmax was 6.8 +/- 6.2%. The difference between laboratories is most probably due to variations in acquisition protocols and analysis programs: 19 laboratories with 18 different protocols and 8 different programs. The dynamics were found to be repeatable and suitable for calibration purposes for radionuclide renography programs and protocols as well as for multicentre comparisons.

Finland

Isolation of mycobacteria from indoor swimming pools in Finland.

The presence of mycobacteria in seven indoor pools in Finland was evaluated by multiple culture methods. Replicate samples, with and without inactivation of chlorine by sodium thiosulfate, were cultured in two laboratories. Laboratory I used two methods: (A) no decontamination and (B) cetylpyridinium chloride (0.005%, 20 min); and Laboratory II two methods: (C) cetylpyridinium chloride (0.005%, 18 h) and (D) oxalic acid (5%, 15 min). Samples processed by methods (A) and (B) were cultured on different egg media of pH 6.3 or 5.8; by method (C) on Middlebrook and Cohn 7H10 (+OADC) agar of pH 5.5; and by method (D) on Middlebrook and Cohn 7H10 agar (+OADC) with cycloheximide (500 microg/ml). Mycobacteria were recovered from five (71%) of seven pools. Detection of mycobacteria depended on the method used. High isolation rates (36-46% of the samples) were obtained by methods (A), (B) and (D). Contamination was a problem only with method (A). Inactivation of chlorine had a variable impact on mycobacterial detection. Isolates included M. kansasii, M. gordonae, M. fortuitum complex, M. sphagni, and M. vaccae, as well as M. simiae-like and M. chubuense-like organisms. In addition, a group of slowly growing and a group of rapidly growing isolates with previously unknown fatty acid and alcohol composition were isolated. No M. avium was detected. Mycobacterial counts were highest in a small pool with high temperature, low pH, and low content of free available chlorine.

Finland