PubMed HealthSearch

PubMed · 8351837

Pulse modulation detection in human motion vision.

Abstract

We present data on the human sensitivity to temporal pulse modulations of target velocity. We measured threshold detection modulation amplitudes for pulse-shaped speed modulations, as a function of pulse duration and temporal frequency. At short pulse durations (up to 50 msec) and low modulation frequency (1 Hz), detection amplitudes are ruled by Bloch's law: the product of pulse duration and threshold modulation amplitude is a constant. This constant corresponds to a position modulation with an amplitude of 3 arc min in a coordinate frame that moves at the average speed (3 deg/sec) of the target. At longer pulse durations we find deviations from Bloch's law. Speed modulation thresholds are not critically dependent on target luminance contrast. These results are modeled by a modulation detection process in two stages. A functional description of the first stage is filtering of the true speed modulation signal by a second order low-pass filter with a characteristic time constant of 20-25 msec. The second (decision) stage is variance detection: modulations are detected when the variance of the filtered modulation function exceeds a certain threshold variance. The square-root threshold variance is estimated 8-10%. This two-parameter model accurately predicts the measured dependence of pulse modulation detection thresholds on pulse duration and pulse density.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H P Snippe, P Werkhoven. Pulse modulation detection in human motion vision.. https://doi.org/10.1016/0042-6989(93)90185-y

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Beta-globin haplotypes from blood spots for follow-up of newborn hemoglobinopathy screening.

The inheritance of sickle-cell anemia upon the background of the major beta-globin gene cluster haplotypes has been associated with differing risks for major organ failure, and more recently with response to hydroxyurea treatment. Early identification of beta-globin haplotypes in individuals with sickle-cell anemia may be a clinically useful prognostic factor for severity of disease expression. This report describes the use of whole-blood spots on filter papers from newborn hemoglobinopathy screening for beta-globin gene cluster haplotyping by the polymerase chain reaction.

Filtration

Automatic filter placement device for region of interest (ROI) fluoroscopy.

In Region of Interest (ROI) Fluoroscopy, an ROI filter is inserted into the x-ray beam in order to decrease the patient exposure in the peripheral part of the field of view. A filter placement device has been designed and constructed for the practical implementation of ROI fluoroscopy. When unmodified spot films are required during fluoroscopic procedures, an electronic signal from the high voltage generator triggers the filter placement device to remove the ROI filter automatically from the field of view and to reinsert it after the conclusion of the spot film exposure. The filter placement device is easily fastened to existing tracks on undertable tube fluoroscopic collimators. A transmission ionization chamber may be placed above the filter assembly so that radiation to the patient may be monitored during ROI fluoroscopic procedures. The mechanical design is compact and involves only one miniature gear-head motor. The filter placement device allows rapid filter positioning in 200 ms so that there is no interference with spot filming. A simple electronic circuit provides 8 volts for rapid motion of the filter support arm and 4 volts for holding the filter in place. This device demonstrates that ROI fluoroscopy with its associated large reduction in patient integral dose can be practically implemented in standard fluoroscopic equipment.

Filtration