PubMed HealthSearch

PubMed · 8364152

Conformational transitions using molecular dynamics with minimum biasing.

Abstract

The molecular dynamics algorithm (MD), which simulates intramolecular motions on the subnanosecond timescale, has been modified to allow the investigation of slow conformational transitions that do not necessarily occur spontaneously in MD simulations. The method is designated CONTRA MD (CONformational TRAnsitions by Molecular Dynamics with minimum biasing). The method requires the prior definition of a single conformational variable that is required to vary monotonically from an initial conformation to a final target conformation. The simulation is broken up into a series of short free MD segments, and we determine, after each segment of MD, whether or not the system has evolved toward the final conformation. Those segments that do not move the system in that direction are deleted. Those that do move it toward the final conformation are patched together sequentially to generate a single representative trajectory along the transition pathway. The CONTRA MD method is demonstrated first by application to the simultaneous C2'-endo to C3'-endo repucker and anti to syn N-glycosidic torsion transitions in 2'-deoxyadenosine and then to the large-scale bending in phenylalanine transfer RNA.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S C Harvey, H A Gabb. 1993. Conformational transitions using molecular dynamics with minimum biasing.. https://doi.org/10.1002/bip.360330803

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

RadiSeq: a single- and bulk-cell whole-genome DNA sequencing simulator for radiation-damaged cell models.

Objective.To build and validate a simulation framework to perform single-cell and bulk-cell whole genome sequencing simulation of radiation-exposed Monte Carlo (MC) cell models to assist radiation genomics studies.Approach.Sequencing the genomes of radiation-damaged cells can provide useful insight into radiation action for radiobiology research. However, carrying out post-irradiation sequencing experiments can often be challenging, expensive, and time-consuming. Although computational simulations have the potential to provide solutions to these experimental challenges, and aid in designing optimal experiments, the absence of tools currently limits such application. MC toolkits exist to simulate radiation exposures of cell models but there are no tools to simulate single- and bulk-cell sequencing of cell models containing radiation-damaged DNA. Therefore, we aimed to develop a MC simulation framework to address this gap by designing a tool capable of simulating sequencing processes for radiation-damaged cells. Main results.We developed RadiSeq-a multi-threaded whole-genome DNA sequencing simulator written in C++. RadiSeq can be used to simulate Illumina sequencing of radiation-damaged cell models produced by MC simulations. RadiSeq has been validated through comparative analysis, where simulated data were matched against experimentally obtained data, demonstrating reasonable agreement between the two. Additionally, it comes with numerous features designed to closely resemble actual whole-genome sequencing. RadiSeq is also highly customizable with a single input parameter file.Significance.RadiSeq enables the research community to perform complex simulations of radiation-exposed DNA sequencing, supporting the optimization, planning, and validation of costly and time-intensive radiation biology experiments. This framework provides a powerful tool for advancing radiation genomics research.

Monte Carlo Method

Neutron fluence and energy spectra around the Varian Clinac 2100C/2300C medical accelerator.

We have simulated the head geometry of a Varian Clinac 2100C/2300C medical accelerator in a Monte Carlo calculation to produce photoneutrons and transport them through the head shielding into a typical therapy room (modeled by a test cell at Varian Associates). The fast neutron leakage fluence and energy spectra have been calculated at 7 positions around the linac head for typical beam operation at 10, 15, 18 and 20 MV. The results of these calculations have been compared with limited measurements made using the same model accelerator operating in a Varian test cell. Calculations were also made for the fluence and energy spectra outside the head with no surrounding concrete walls, floor or ceiling to eliminate the effects of scattering from concrete. Comparisons were also made with calculations using a much simplified head geometry. The results indicate that the calculations using the complex head geometry compare, within the uncertainties, with the measurements. The simple head geometry leads to differences of a factor of 2 from the complex geometry. Results of these calculations can be used to calculate fast neutron transmission through various shielding configurations and through labyrinths.

Monte Carlo Method

Energy deposition pattern from tritium and different energy photons--a comparative study.

Energy deposition patterns of beta particles from tritium decay have been analyzed in comparison with photon radiation in the energy range from 12 to 1250 keV. Energy deposition was modeled by Monte Carlo means using electron tracks in water vapor with a complete follow up of delta electrons. Ionizations have been used as representative of track structure. Frequencies of clusters on a nanometer scale and their spatial distribution in spherical targets representing cell nuclei have been derived. Cluster analysis has been carried out by implementing a k-means method. Frequencies of ionization clusters from tritium are similar to 60-100 keV photons. Spatial distribution of clusters from tritium closely match approximately 70 keV photons up to 2 microm separation.

Monte Carlo Method