PubMed HealthSearch

PubMed · 8364851

The Vector System for dynamic gait analysis.

Abstract

This article explores dynamic versus static biomechanics, quantitative versus qualitative data, and practical uses in a clinical setting for the Vector System of gait analysis. This system uses a video camera connected to a computer to analyze gait.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A S Woodle, S Elliott. 1993. The Vector System for dynamic gait analysis.. https://pubmed.ncbi.nlm.nih.gov/8364851/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of post-injury spinal position on canal occlusion in a cervical spine burst fracture model.

STUDY DESIGN: The canal space of burst-fractured, human cervical spine specimens was monitored to determine the extent to which spinal position affected post-injury occlusion. OBJECTIVE: To test the null hypothesis that there is no difference in spinal canal occlusion as a function of spinal positioning for a burst-fractured cervical spine model. SUMMARY OF BACKGROUND DATA: Although previous studies have documented the effect of spinal positioning on canal geometry in intact cadaver spines, to the authors' knowledge, none has examined this relationship specifically in a burst fracture model. METHODS: Eight human cervical spine specimens (levels C1 to T3) were fractured by axial impact, and the resulting burst injuries were documented using post-injury radiographs and computed tomography scans. Canal occlusion was measured using a custom transducer in which water was circulated through a section of flexible tygon tubing that was passed through the spinal canal. Any impingement on the tubing produced a rise in fluid pressure that was monitored with a pressure transducer. Each spine was positioned in flexion, extension, lateral (and off-axis) bending, axial rotation, traction, and compression, while canal occlusion and angular position were monitored. Occlusion values for each position were compared with measurements taken with the spine in neutral position. RESULTS: Compared with neutral position, compression, extension, and extension combined with lateral bending significantly increased canal occlusion, whereas flexion decreased the extent of occlusion. In extension, the observed mechanism of occlusion was ligamentum flavum bulge caused by ligament laxity resulting from reduced vertebral body height. CONCLUSIONS: Increased compression of the spinal cord after injury may lead to more extensive neurologic loss. This study demonstrated that placing a burst-fractured cervical spine into either extension or compression significantly increased canal occlusion as compared with occlusion in a neutral position.

Biomechanical Phenomena

Mechanical stability of thoracolumbar pedicle screw fixation. The effect of crosslinks.

STUDY DESIGN: Pedicle screw fixation for unstable thoracolumbar spine injuries is relatively new. The effect of one or two crosslinks on rotational and lateral bending stiffness was studied. OBJECTIVE: To determine the rotational and bending stiffness values of thoracolumbar fractures fixed by the AO's internal fixation system with zero, one, or two crosslinks. METHODS: Eight embalmed thoracolumbar spine segments. (T12-L2) were instrumented at T12 and L2 with a pedicle screw-rod system. Rotational stiffness was determined for 10 cycles to 2.5 degrees, 3.5 degrees, and 5 degrees of rotation, with and without one or two crosslinks, and lateral bending stiffness for 10 cycles to 0.25, 0.40, and 0.50 inch. The results showed a clear trend toward increased stiffness with crosslinks. RESULTS: The stiffness values of the two-crosslink construct at 2.5 degrees and 3.5 degrees of rotation were significantly higher than those of the zero-crosslink system. Also, the bending stiffness of the two-crosslink construct was significantly higher than that of no-crosslink system at all of the displacements. CONCLUSIONS: Rotational stiffness values of the two-crosslink construct were significantly higher than those of the zero-crosslink system, at 2.5 degrees and 3.5 degrees of rotation. Lateral bending stiffness of the two-crosslink system was higher than that of the zero-crosslink system at all levels of displacement.

Biomechanical Phenomena

The effect of bone quality on pedicle screw loading in axial instability. A synthetic model.

STUDY DESIGN: In this biomechanical analysis of pedicle screw bending moments, custom-fabricated vertebral analogues were loaded in axial compression to produce sagittal bending forces. Moments were measured directly from internally instrumented pedicle screws. OBJECTIVES: To establish the role of cancellous vertebral modulus on pedicle screw bending moments within the vertebral body and the vertebral pedicle. SUMMARY OF BACKGROUND DATA: Pedicle screws are often used to manage axial instability of the spine. Clinical studies report a high incidence of screw bending failure, resulting in kyphosis and pain in some patients. Factors predisposing to bending failure are not well understood, although recent studies have shown that vertebral morphometry is important. METHODS: Axially canullated 7.0-mm pedicle screws, internally instrumented with paired strain gauges, were inserted into analogue vertebrae of uniform dimension. Cancellous modulus was varied from 25-100 MPa. Screws were rigidly mounted to a vertical testing frame, and axial loads were applied to the superior vertebral endplate, producing sagittal bending moments. Moments were recorded from gauges applied in the intrapedicular and intravertebral portions of the screw. Mean moments were compared using a Student's t test, with significance defined as P < 0.05. RESULTS: Cancellous modulus did not affect bending moments experienced in either the intrapedicular or intravertebral portions of the pedicle screws. Gauge accuracy was excellent, and with no gauge drift. CONCLUSIONS: Although small changes in pedicle morphometry can alter screw bending moments significantly, changes in cancellous modulus had no measurable impact on bending moments at these same loads. Bone density is likely to play a limited role in screw bending failure.

Biomechanical Phenomena