PubMed HealthSearch

PubMed · 8377513

A general-purpose system for long-term recording from a microelectrode array coupled to excitable cells.

Abstract

A PC-based system for acquisition and processing of data from excitable cells on a microelectrode array is described. Simple and low-cost amplification and filtering custom stages are used. A software package for processing acquired data is proposed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Martinoia, M Bove, G Carlini, C Ciccarelli, M Grattarola, C Storment, G Kovacs. 1993. A general-purpose system for long-term recording from a microelectrode array coupled to excitable cells.. https://doi.org/10.1016/s0165-0270(05)80013-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design parameters of pulsed wave ultrasonic Doppler blood flowmeter.

Pulse wave Doppler techniques promise the ability to make more effective measurements of dynamic cardiovascular functions. Quantitative measurement of blood flow can be achieved by using the pulse wave Doppler system. This paper discusses the design parameters of the pulse wave Doppler blood flowmeter (PW Doppler) with respect to the physiological system.

Amplifiers, Electronic

Spatial aspects of reproduced sound in small rooms.

This paper reports on the influence of individual reflections on the auditory spatial aspects of reproduced sound. The sound field produced by a single loudspeaker positioned in a normal listening room has been simulated using an electroacoustical synthesis of the direct sound, 17 individual reflections and the reverberant field. The threshold of detection was measured using the method of adjustment for five reflections using three subjects for noise and speech. The thresholds have been measured for two simulated situations (1) a loudspeaker with a frequency independent directivity characteristics and frequency independent absorption coefficients of the room surfaces and (2) a loudspeaker with directivity similar to a standard two-way system and absorption coefficients according to measurements of real materials. The results have shown that subjects can reliably distinguish between timbre and spatial aspect of the sound field, that the spectral energy above 2 kHz of the individual reflection determines the importance of the reflection for the spatial aspects, and that only the first order floor reflection will contribute to the spatial aspects.

Amplifiers, Electronic

An adaptive noise canceller for hearing aids using two nearby microphones.

An adaptive noise cancellation scheme based on two-stage adaptive filtering as proposed by Van Compernolle [Proceedings of the IEEE International Conference on Acoustics, Speech and Signal Processing (IEEE, New York, 1990)] was tested for two identical directional microphones mounted in an endfire configuration within a single behind-the-ear (BTE) hearing aid. Speech intelligibility tests were carried out with two normal hearing subjects and three hearing aid users with moderate hearing losses, in a realistic test environment using open set words and sentences. A significant improvement, on average more than 5 dB, of speech reception threshold (SRT) in background noise was obtained.

Amplifiers, Electronic