PubMed Health⌕ Search

PubMed · 8379754

Equipment for thoracoscopy.

Abstract

The combining of miniaturized video technology with thoracoscopy now allows surgeons to perform a variety of thoracic procedures percutaneously. Both rigid and flexible video thoracoscopes are available. The rigid endoscope has a camera located proximally at the eye-piece and is capable of excellent resolution. However, visualization of the entire pleural cavity is difficult because of the rigid chest wall. Placing the video camera at the distal end of a flexible thoracoscope, as in the electronic video thoracoscope (EVE-L; Fujinon, Wayne, NJ), yields better visualization of these relatively inaccessible areas. However, disadvantages of the flexible thoracoscope include increased expense and complexity, reduced resolution as compared to rigid systems, and the need for a strobed light source, thus making video-assisted surgery more difficult. Thoracoscopic wedge excisions of the lung are now possible because of the adaptation of gastrointestinal staplers for percutaneous use. The initial design consisted of a reloadable 30-mm disposable stapler. Newer models, however, have a longer staple line and some are reusable. Future refinements may allow the head of the instrument to articulate, thus permitting it to be applied to the lung at various angles. Thoracoscopic ports that provide an air-tight seal are available but are not essential; therefore, standard thoracotomy instruments can be utilized through small open incisions. Specialized disposable thoracoscopic instruments are also available, including scissors, dissectors, and fan retractors. It is hoped that the future will bring improved optics, better staplers, and refined percutaneous instrumentation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M S Allen, V F Trastek, R C Daly, C Deschamps, P C Pairolero. 1993. Equipment for thoracoscopy.. https://doi.org/10.1016/0003-4975(93)90931-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Global Genomic Surveillance.

Global genomic surveillance has emerged as a foundational pillar of public health in the twenty-first century, enabling real-time tracking of pathogen evolution and informing outbreak response. This chapter examines the strategic architecture of global genomic surveillance, focusing on its application to arboviruses such as chikungunya virus (CHIKV). It explores the integration of genomic data with epidemiological, clinical, and environmental information within a One Health framework, while addressing critical challenges in governance, equity, and interoperability. The discussion covers the entire genomic surveillance workflow, from sample collection and sequencing to bioinformatic analysis and phylogenetic inference, and highlights the transformative role of artificial intelligence (AI) in predictive surveillance. By analyzing global initiatives, operational barriers, and emerging technologies, this chapter underscores the necessity of sustainable, equitable, and interoperable genomic systems to proactively address current and future infectious disease threats.

Humans↗

Systematic Dissection of Key Driver Perturbation Signatures in Single Cells via ECCITE-seq.

CRISPR screens, such as expanded CRISPR-compatible cellular indexing of transcriptomes and epitopes by sequencing (ECCITE-seq), enable the simultaneous measurement of transcriptomes, gRNA identity, and cell-surface protein expression at single-cell resolution to systematically interrogate gene function. This platform provides a powerful and scalable experimental approach for validating disease-associated regulators identified by large-scale association studies and other computational methods, including network-based analyses of multi-omics data. Here, as an example application, we describe an ECCITE-seq framework to characterize the transcriptomic consequences of perturbing multiple neuronal key driver genes associated with Alzheimer's disease (AD) in human-induced pluripotent stem cell (hiPSC)-derived neurons. More broadly, by integrating customized pooled gRNA libraries with different CRISPR effectors across multiple cell types, this approach allows for the assessment of the regulatory impact of candidate genes implicated in development and disease processes.

Humans↗

Identification of Genome-Wide Chromatin Structural Aberration in Cancer by Hi-C Analysis.

Aberrant three-dimensional genome organization is a hallmark of cancer, often driving oncogene activation through mechanisms such as enhancer hijacking. High-throughput chromosome conformation capture (Hi-C) maps these interactions on a genome-wide scale. Unlike earlier dilution-based methods, in situ Hi-C performs proximity ligation within intact nuclei, minimizing random ligation noise and enabling fine-scale structure detection. This chapter describes an optimized in situ Hi-C protocol tailored for cancer cell lines using MboI digestion and biotin-mediated pull-down to generate high-complexity libraries. We further outline a computational workflow that extends beyond standard topological mapping of compartments and topologically associating domains to identify cancer-specific aberrations. Specifically, we focus on detecting chromosomal rearrangements (structural variants) and characterizing the distinct circular topology of extrachromosomal DNA. This integrated experimental and analytical framework provides the necessary tools to dissect the spatial dysregulation underlying tumor evolution.

Humans↗