PubMed HealthSearch

PubMed · 8410234

The sequential hook insertion technique for universal spine instrumentation application. Technical note.

Abstract

A new technique of universal spine instrumentation insertion for the management of thoracic and lumbar spine instability is presented and the results in 10 patients are described. The technique involves the sequential insertion of Texas Scottish Rite Hospital (TSRH) central-post hooks, followed by hook fixation to the rod; force is then applied with correction of deformity, if needed. This allows for methodical, safe, and rapid instrumentation insertion. The new TSRH central-post hook configuration permits manipulation of the hook/rod relationships to the advantage of the surgeon (and patient) by providing more room for both hook insertion and hook/rod fixation. This technique has reduced operative time, facilitated ease of deformity correction, and provided uniformly acceptable early postsurgical results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E C Benzel, P A Ball, N G Baldwin, E P Marchand. 1993. The sequential hook insertion technique for universal spine instrumentation application. Technical note.. https://doi.org/10.3171/jns.1993.79.4.0608

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Steam sterilizable probes for dissolved oxygen measurement. Reprinted from Biotechnology and Bioengineering, Vol. VI, Issue 4, Pages 457-468 (1964).

Steam-sterilizable membrane probes for monitoring the dissolved oxygen level in fermentors, or the oxygen content of gas streams, are described. The probes have a silver cathode, a lead anode, and an acetate buffer as an electrolyte. The membrane is Teflon. The current output of the probes in the absence of oxygen is negligible.

Equipment Design

Performance-based standards: safety instrumented functions and safety integrity levels.

This paper discusses two international performance-based standards, ANSI/ISA S84.01 and IEC d61508 and the requirements they place upon companies that rely on electrical, electronic and programmable electronic systems to perform safety functions. Performance-based regulations are also discussed and common safety elements between the standards and regulations are identified. Several risk analysis techniques that can be used to comply with the aforementioned requirements are discussed and a simple example is used to illustrate the use, advantages and disadvantages of the techniques. The evaluation of safety integrity level (SIL) of the Safety Instrumented System (SIS) in terms of the probability to fail to function is outside the scope of this paper.

Equipment Design