PubMed Health⌕ Search

PubMed · 841063

Quantitative external counting techniques enabling improved diagnostic and therapeutic decisions in patients with well-differentiated thyroid cancer.

Abstract

A quantitative technique is described which allows the physician to predict more accurately whether a recurrent or metastatic well-differentiated thyroid carcinoma is amenable to radioiodine-131 therapy or is better treated by other means. A calibrated uptake probe and scaler system is used to obtain conjugate view (i.e., diametrically opposed) counting rates for both the whole body and for any areas of abnormal uptake (lesion) at 24,48 annd 72 hours following the administration of 2 mCi 131l. Quantitative calculations accounting for patient attenuation, lesion size and geometrical factors then provide a determination of the lesion uptake as well as the effective half-life of 131l in the lesion. The radiation dose which would be delivered to the lesion by a given therapeutic amount of 131l may then be calculated to help determine the desirability of 131l treatment. The results of patient studies indicate the potential benefit of such quantitative evaluation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S R Thomas, H R Maxon, J G Kereiakes, E L Saenger. 1977. Quantitative external counting techniques enabling improved diagnostic and therapeutic decisions in patients with well-differentiated thyroid cancer.. https://doi.org/10.1148/122.3.731

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radiation quality of tritium.

Tritium occurs from both natural and manufactured processes. In the environment, tritium can exist in the form of tritiated water (HTO) and in an organic form known as organically-bound tritium (OBT). Although, the concentrations of environmental OBT are relatively low, there is concern that current risk factors may underestimate the risk from OBT. Because tritium poses an internal hazard at cellular levels, microdosimetric techniques provide suitable tools for the study of radiation quality of tritium. In this study, microdosimetric simulations are performed for tritium uniformly distributed in a medium, and for tritium bound to biologically critical sites of dimensions from 10 nm to 2 microm. Results of local energy density are different for these two cases in microscopic regions. Based on the spatial distribution of energy deposition, dose mean lineal energies are calculated for tritium in forms of HTO and OBT. The dose mean lineal energies of OBT are about a factor of 1.7 higher than those of HTO in a wide range of target dimensions of biological interest. The results are consistent with radiobiological findings that OBT is about twice as effective as that of HTO.

Half-Life↗

Fewest switches adiabatic surface hopping as applied to vibrational energy relaxation.

In this contribution quantum/classical surface hopping methodology is applied to vibrational energy relaxation of a quantum oscillator in a classical heat bath. The model of a linearly damped (harmonic) oscillator is chosen which can be mapped onto the Brownian motion (Caldeira-Leggett) Hamiltonian. In the simulations Tully's fewest switches surface hopping scheme is adopted with inclusion of dephasing in the adiabatic basis using a simple decoherence algorithm. The results are compared to the predictions of a Redfield-type quantum master equation modeling using the classical heat bath force correlation function as input. Thereby a link is established between both types of quantum/classical approaches. Viewed from the latter perspective, surface hopping with dephasing may be interpreted as "on-the-fly" stochastic realization of a quantum/classical Pauli master equation.

Half-Life↗