PubMed HealthSearch

PubMed · 8423852

Visible flicker from invisible patterns.

Abstract

Using a laser interferometer we can create grating patterns of high optical contrast (interference fringes) directly on the retina. With coarse fringe patterns, the alternating light and dark bars of the pattern can be seen, but the bars of the finest fringes are not subjectively resolved. We report here that when we rapidly modulate the contrast of a fine fringe pattern (keeping overall luminance constant), observers experience flicker, even if the fringes are too finely spaced to be perceived as a grating. For this flicker to be seen, the pattern needs to be resolvable by the photoreceptors themselves, but not necessarily by later stages of visual processing. It can be explained if, in man, signals associated with individual cone receptors do not depend linearly on light intensity, but instead are scaled by a fast sensitivity-regulating or light-adaptation mechanism. Contrast-modulation flicker is not demonstrable in rod vision; rod vision therefore lacks such a local adaptation process.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D I MacLeod, S He. 1993-01-21. Visible flicker from invisible patterns.. https://doi.org/10.1038/361256a0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Moving segments region of interest attenuator for x-ray fluoroscopy.

Region of interest (ROI) imaging has previously been proposed as a means of reducing x-ray fluoroscopy radiation dose. Previous ROI attenuators made of partially attenuating metal plates change beam quality, which may lead to uncertainty in image restoration procedures. The design and construction of a prototype moving segments ROI attenuator (MS-ROI), which maintains beam quality across the whole field of view is described. The x-ray beam intensity is halved by 36 lead segments which are rapidly rotated between the x-ray tube and patient, with a central hole projecting a circular ROI at full intensity. Image processing techniques with automatic detection of the ROI boundary were used to homogenize image brightness across the whole image. Images restored using these techniques were judged to be visually acceptable, with a good match between pixel values inside and outside the ROI. Image contrast within the ROI was improved by 18% due to reduced scatter and veiling glare from the periphery. The introduction of the MS-ROI attenuator also results in a 48% increase in statistical noise in the area outside the ROI, with no significant change in object contrast. The patient entrance dose measured using the dose area product (DAP) method was reduced by 53.4% under manual exposure control, with the dose to operators reduced by 48.4% under automatic brightness control. Further work is needed to determine whether the attenuator can be used with pulsed fluoroscopy, and to reduce vibrational effects on the ROI boundary. The MS-ROI attenuator provides a more constant ratio of central-to-peripheral image intensity, and maintains uniform beam quality and image contrast across the whole image in comparison to simple metal plate attenuators.

Contrast Sensitivity

An empirical explanation of brightness.

In this second part of our study on the mechanism of perceived brightness, we explore the effects of manipulating three-dimensional geometry. The additional scenes portrayed here demonstrate that the same luminance profile can elicit different sensations of brightness as a function of how the objects in the scene are arranged in space. This further evidence confirms the implication of the scenes presented in the accompanying paper, namely that sensations of relative brightness-including standard demonstrations of simultaneous brightness contrast-cannot arise by computations of local contrast. The most plausible explanation of the full range of perceptual phenomena we have described is an empirical strategy that links the luminance profile in a visual stimulus with an association (the percept) that represents the profile's most probable real-world source.

Contrast Sensitivity

Are recognition deficits following occipital lobe TMS explained by raised detection thresholds?

It is known that transcranial magnetic stimulation (TMS) administered over the occipital pole suppresses recognition of visual objects. Our aim was to ascertain whether this suppression can be interpreted as a change in visual contrast threshold. Four subjects detected the orientation of an U-shaped hook flashed for 21 ms. Under control conditions, mean contrast threshold was found at 0.88 log units Weber contrast. Thresholds were raised if TMS was applied 40-200 ms after the visual stimulus. Maximum elevation was 1.67 log units under TMS at 120 ms stimulus onset asynchrony. This phenomenon can be interpreted as a reduction in signal-to-noise ratio of the visual stimuli by TMS, which can be compensated for by increasing the contrast of the stimuli.

Contrast Sensitivity