PubMed Health⌕ Search

PubMed · 8441173

Hyaluronate in total hip replacement.

Abstract

We studied the composition of the fluid in joint cavity of the hip joint in primary osteoarthritis (OA) from samples obtained at primary total hip replacement (THR) operations (N = 21) and in the THR pseudojoint, where the samples were obtained in revision operations for the common type of prosthesis loosening (N = 17). Protein concentrations differed little in both groups (31.8 +/- 1.9 mg/ml vs 34.4 +/- 1.9 mg/ml, p < 0.01), which suggests similar transcapillary flow in the degenerative hip joint and THR pseudojoint. Hyaluronate was found in OA joint fluid and in the fluid from the THR pseudojoint (2.21 +/- 0.23 mg/ml vs 0.43 +/- 0.04 mg/ml, p < 0.005) and high performance liquid chromatography (HPLC) analysis, calibrated using laser light scatter analyzed molecular weight standards, disclosed the low molecular weight nature of the OA synovial fluid compared to the THR pseudojoint fluid (1.12 +/- 0.84 x 10(6) vs 2.63 +/- 1.13 x 10(6) Da, NS). This suggests that THR arthroplasties cause an adaptive tissue response and formation of fibroblast-like B type lining cells able to synthesize and secrete hyaluronate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Saari, S Santavirta, D Nordström, P Paavolainen, Y T Konttinen. 1993. Hyaluronate in total hip replacement.. https://pubmed.ncbi.nlm.nih.gov/8441173/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement.

In Europe and the USA combined, over half a million people had a hip joint replaced in 2005, contributing to the increasing number of radiotherapy patients with metallic hip prostheses. The treatment plan for external beam radiation therapy is based on the delineation of the anatomy in the planning CT scan. When implanted objects of high atomic number (Z) material are present, however, severe image artefacts are generated in conventional CT, strongly hindering the ability to delineate some organs. This is particularly the case for the planning of prostate patients with hip prostheses. This short communication presents the use of a new imaging modality, megavoltage cone-beam CT, to complement the regular CT for target definition of prostate cancer treatment of patients with hip replacements.

Hip Prosthesis↗

Stem damage during implantation of modular hip prostheses.

Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to assess if stem holders of modular prostheses can induce any stem damage, and if so, to identify the features that provide minimal damage. Two different stem holder connector designs were investigated. The surface of the stem cavity was inspected to identify the damage caused by the use of the two connectors after a simulated surgical handling. Both connectors induced some damage, with significantly more damage being caused by a supposedly improved design. Scars due to contact with the stem holder were observed on the stem cavity surface. This may be sufficient to trigger increased fretting damage during service life, causing the production of fretting debris.