PubMed HealthSearch

PubMed · 8451252

Solid oral dosage forms.

Abstract

The oral route of drug administration is the most convenient for patients, with tablets emerging as the most popular solid oral dosage form used today. Standard compressed, controlled-release and coated tablets are the most common form of solid oral dosages. A wide range and diversity of ingredients are often included in tablet formulations. A knowledge of the difference between tablet and capsule formulations should enable nurses to improve patient compliance with respect to solid oral dosage forms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Helliwell, D Taylor. 1993. Solid oral dosage forms.. https://pubmed.ncbi.nlm.nih.gov/8451252/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effective treatment of cobalamin deficiency with oral cobalamin.

Because cobalamin deficiency is routinely treated with parenteral cobalamin, we investigated the efficacy of oral therapy. We randomly assigned 38 newly diagnosed cobalamin deficient patients to receive cyanocobalamin as either 1 mg intramuscularly on days 1, 3, 7, 10, 14, 21, 30, 60, and 90 or 2 mg orally on a daily basis for 120 days. Therapeutic effectiveness was evaluated by measuring hematologic and neurologic improvement and changes in serum levels of cobalamin (normal, 200 to 900 pg/mL) methylmalonic acid (normal, 73 to 271 nmol/L), and homocysteine (normal, 5.1 to 13.9 micromol/L). Five patients were subsequently found to have folate deficiency, which left 18 evaluable patients in the oral group and 15 in the parenteral group. Correction of hematologic and neurologic abnormalities was prompt and indistinguishable between the 2 groups. The mean pretreatment values for serum cobalamin, methylmalonic acid, and homocysteine were, respectively, 93 pg/mL, 3,850 nmol/L, and 37. 2 micromol/L in the oral group and 95 pg/mL, 3,630 nmol/L, and 40.0 micromol/L in the parenteral therapy group. After 4 months of therapy, the respective mean values were 1,005 pg/mL, 169 nmol/L, and 10.6 micromol/L in the oral group and 325 pg/mL, 265 nmol/L, and 12.2 micromol/L in the parenteral group. The higher serum cobalamin and lower serum methylmalonic acid levels at 4 months posttreatment in the oral group versus the parenteral group were significant, with P < .0005 and P < .05, respectively. In cobalamin deficiency, 2 mg of cyanocobalamin administered orally on a daily basis was as effective as 1 mg administered intramuscularly on a monthly basis and may be superior.

Administration, Oral

Chiral chromatographic method to determine the enantiomers of halofantrine and its main chiral desbutyl metabolite in erythrocytes.

We describe a direct liquid chromatographic method with spectrofluorimetric detection to quantify the two enantiomers of halofantrine and the two enantiomers of its main chiral N-monodesbutylated metabolite in erythrocyte pellets. The method involves a Chiralpak AD column and a rapid one-step extraction procedure with acetonitrile. The method was validated for the four enantiomers within the range 0-1000 ng/ml. The absence of stereoconversion was studied in samples stored frozen for up to eight months. The optical rotation of the halofantrine and metabolite enantiomers was determined after separation on a semi-preparative Chiralcel OD column with polarimetric detection.

Administration, Oral

Double column-switching high-performance liquid chromatographic method for the determination of TAK-603 and its metabolites in human serum.

A double column-switching high-performance liquid chromatographic (HPLC) method for the determination of concentrations for TAK-603 (T) and its metabolites, T-72258 (M-I) and T-72294 (M-III), in human serum was developed. The analytes were extracted with ethyl acetate from human serum samples treated with triethylamine and injected into the HPLC system. Separation of the analytes was performed on the HPLC system with double column-switching technique. The mobile phases A and B for the first column and the mobile phase C for the second column used were a mixture of methanol-10 mM aqueous ammonium acetate solution (1:1, v/v), methanol and a mixture of methanol-10 mM aqueous ammonium acetate solution (11:9, v/v), respectively. The eluate was monitored with a UV detector at a wavelength of 253 nm. The work-up procedure was reproducible and more than 90% of the analytes could be recovered from human serum. The lower limits of quantitation were all 1 ng/ml for the analytes when 0.5 ml of human serum was used. Standard curves were linear with a correlation coefficient (R) of more than 0.999 in the range of 1-500 ng/ml for T, M-I and M-III in human serum. The intra- and inter-day precision of the method for the various analytes were below 4.8%. The accuracy was good with the deviations between spiked and calculated concentrations of the analytes being within 11.0%. The method was successfully applied to analyze serum samples after an oral administration of T to healthy male volunteers.

Administration, Oral