Designing and implementing a comprehensive quality assurance program for bedside glucose testing.

Abstract

A program for bedside glucose testing has been successfully implemented and in operation at Sharp Memorial Hospital since October 1990. The nursing staff training and certification process focuses on gaining an understanding of the issues and skills needed to routinely perform the tests to laboratory quality standards. Routine quality control checks are performed to ensure the accuracy and precision of the glucose values obtained on patients, thus maintaining quality in the process. Instituting this comprehensive QA program for bedside glucose testing has enabled us to improve the accuracy of our measurements and increase the quality of our patient care.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J B Jurf, E G Outlaw. Designing and implementing a comprehensive quality assurance program for bedside glucose testing.. https://doi.org/10.1177/014572179301900203

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Building measurement and data collection into medical practice.

Clinicians can use data to improve daily clinical practice. This paper offers eight principles for using data to support improvement in busy clinical settings: 1) seek usefulness, not perfection, in the measurement; 2) use a balanced set of process, outcome, and cost measures; 3) keep measurement simple (think big, but start small); 4) use qualitative and quantitative data; 5) write down the operational definitions of measures; 6) measure small, representative samples; 7) build measurement into daily work; and 8) develop a measurement team. The following approaches to using data for improvement are recommended. First, begin with curiosity about outcomes or a need to improve results. Second, try to avoid knee-jerk, obstructive criticism of proposed measurements. Instead, propose solutions that are practical, goal-oriented, and good enough to start with. Third, gather baseline data on a small sample and check the findings. Fourth, try to change and improve the delivery process while gathering data. Fifth, plot results over time and analyze them by using a control chart or other graphical method. Sixth, refine your understanding of variation in processes and outcomes by dividing patients into clinically homogeneous subgroups (stratification) and analyzing the results separately for each subgroup. Finally, make further changes while measuring key outcomes over time. Measurement and improvement are intertwined; it is impossible to make improvements without measurement. Measuring and learning from each patient and using the information gleaned to test improvements can become part of daily medical practice in local settings.

Blood Glucose Self-Monitoring

Validation of home blood glucose meters with respect to clinical and analytical approaches.

OBJECTIVE: To evaluate the clinical and analytical accuracy of home blood glucose meters. RESEARCH DESIGN AND METHODS: Six blood glucose meters--Reflolux S (Boehringer Mannheim, Mannheim, Germany), One Touch II (LifeScan, Milpitas, CA), Glucocard Memory (Menarini, Florence, Italy), Precision QID (Medisense, Cambridge, U.K.), HaemoCue (HaemoCue, Angelholm, Sweden), and Accutrend alpha (Boehringer Mannheim, Mannheim, Germany)--were compared with a reference method (Beckman Glucose Analyzer II) under controlled conditions (glucose clamp technique). Validation of the blood glucose meters was accomplished by clinically oriented approaches (error grid analysis), statistical approaches (variance components analysis), and by the criteria of the American Diabetes Association (ADA), which recommend a target variability of < 5%. RESULTS: A total of 1,794 blood glucose monitor readings and 299 reference values ranging from 2.2 to 18.2 mmol/l were analyzed (705 readings < 3.89 mmol/l, 839 readings between 3.89 and 9.99 mmol/l, and 250 readings > 9.99 mmol/l). According to error grid analysis, only Reflolux S and Glucocard M had 100% of estimations within the clinically acceptable zones A and B. Assessment of analytical accuracy revealed substantial differences between the glucose meters after separation of the data into defined glycemic ranges. None of the devices met the ADA criteria. CONCLUSIONS: To evaluate accuracy of blood glucose meters, error grid analysis, as well as statistical models, are helpful means and should be performed together. Analytical performance of currently available home blood glucose meters differs substantially within defined glycemic ranges.

Blood Glucose Self-Monitoring