PubMed Health⌕ Search

PubMed · 8483830

Controlled delivery systems for proteins using polyanhydride microspheres.

Abstract

A method to provide near-constant sustained release of high molecular weight, water-soluble proteins from polyanhydride microspheres is described. The polyanhydrides used were poly(fatty acid dimer) (PFAD), poly(sebacic acid) (PSA), and their copolymers [P(FAD-SA)]. P(FAD-SA) microspheres containing proteins of different molecular sizes--lysozyme, trypsin, heparinase, ovalbumin, albumin, and immunoglobulin--were prepared by a solvent evaporation method using a double emulsion. The microspheres containing proteins were spherical, with diameters of 50-125 microns, and encapsulated more than 80% of the protein, irrespective of the protein used. Enzymatic activity studies showed that encapsulation of enzymes inside polyanhydride microspheres can protect them from activity loss. When not placed inside polyanhydride microspheres, trypsin lost 80% of its activity in solution at 37 degrees C at pH 7.4 in 12 hr, whereas inside the polyanhydride microspheres the activity loss was less than 10% under these conditions. About 47% of the enzymatic activity of heparinase encapsulated in the microspheres was lost at 37 degrees C in 24 hr, while in solution it lost over 90% of its activity. The protein-loaded microspheres displayed near-zero-order erosion kinetics over 5 days as judged by the release of sebacic acid (SA) from the microspheres. The microspheres degraded to form SA and FAD monomers. All proteins were released at a near-constant rate without any large initial burst, irrespective of polymer molecular weight and protein loading. The period of protein release was longer than that of SA and continued protein release was observed even after the microsphere matrix had completely degraded. Differential scanning calorimetric studies demonstrated an interaction between protein and the FAD monomers produced with microsphere degradation. It is likely that the protein interaction with FAD monomers permits formation of water-insoluble protein aggregates which slowly dissolve and diffuse out of the matrix, leading to delayed protein release. For trypsin-loaded microspheres, trypsin lost 40% of its activity during microsphere preparation. Activity studies demonstrated that the sonication process was primarily responsible for activity loss. A reduction in the period of ultrasound exposure decreased the loss of protein activity to around 20%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Tabata, S Gutta, R Langer. 1993. Controlled delivery systems for proteins using polyanhydride microspheres.. https://doi.org/10.1023/a%3A1018929531410

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Laser ablation inductively coupled plasma mass spectrometry assisted insight into ion-selective membranes.

Laser ablation inductively coupled plasma mass spectrometry was used to evaluate ion depth profiles across ion-selective membranes. Advantageously, this approach does not require incorporation of additional components (e.g., chromoionophore) in the membrane composition, as compared to that used in typical potentiometric applications. Moreover, comparison of the distribution of ions in differently pretreated membranes is possible. Concentration profiles of primary and interfering agent (Na+) ions were recorded, for example, of Pb2+-selective poly(vinyl chloride)-based membranes. It was found that the contents and the distribution of Pb(2+) and Na+ ions across the membrane is strongly dependent on the composition of the solutions to which both sides of the membrane are exposed during preconditioning and on the plasticizer included in the membrane formulation. Typical plasticizers, bis(2-ethylhexyl sebacate) (DOS) and the more polar 2-nitrophenyl octyl ether (o-NPOE), were used. It was found that faster ion transport occurs for o-NPOE, and the membrane saturation with Pb2+ ions was achieved within less than 20 h for a 400-microm-thick membrane. In the case of the less polar plasticizer DOS, due to slower rate of ion transport, even after 20 h, the Pb2+ concentration gradients were still visible within the membrane. On the basis of concentration profiles, primary ion diffusion coefficients in both membranes were calculated, and the value obtained for o-NPOE containing membrane was found to be approximately 2 times higher than for its DOS-plasticized counterpart.

Decanoic Acids↗

Novel copolyanhydrides combining strong inherent fluorescence and a wide range of biodegradability: synthesis, characterization and in vitro degradation.

In this work, a novel diacid monomer was synthesized in a very convenient scheme. The monomer is derived from naturally occurring products and emits strong fluorescence when polymerized to polyanhydride. The chemical structure of the monomer dCPS is as follows: HOC(O)ArOC(O)(CH2)2C(O)O--Ar--COOH. Copolyanhydrides composed of dCPS and sebacic acid were further prepared by melt copolycondensation, and characterized by IR, NMR, UV-Vis, DSC and fluorometry. The emission wavelength (lambda(em)) of the copolymers could be tuned by the excitation wavelength (lambda(ex)). Fluorescence intensity increased with the increase of dCPS content. The microspheres fabricated from the copolymer with dCPS content as low as 10% could be clearly visualized with fluorescence microscopy. Either blue or green images of the microspheres could be captured with an excitation of UV and visible light. The degradation rate of the copolyanhydrides decreased as the dCPS fraction increased, and the degradation duration could be modulated from several days to more than three months. In addition, it was found that the copolyanhydrides displayed surface degradation characteristics. In view of the advantages of the novel copolyanhydrides, such as easy preparation, unique inherent luminescent properties, and widely adjustable degradation rate, they might be useful for biomedical engineering.

Decanoic Acids↗