Wire chambers revisited.

Abstract

Detectors used for radioisotope imaging have, historically, been based on scintillating crystal/photomultiplier combinations in various forms. From the rectilinear scanner through to modern gamma cameras and positron cameras, the basic technology has remained much the same. Efforts to overcome the limitations of this form of technology have foundered on the inability to reproduce the required sensitivity, spatial resolution and sensitive area at acceptable cost. Multiwire proportional chambers (MWPCs) have long been used as position-sensitive charged particle detectors in nuclear and high-energy physics. MWPCs are large-area gas-filled ionisation chambers in which large arrays of fine wires are used to measure the position of ionisation produced in the gas by the passage of charged particles. The important properties of MWPCs are high-spatial-resolution, large-area, high-count-rate performance at low cost. For research applications, detectors several metres square have been built and small-area detectors have a charged particle resolution of 0.4 mm at a count rate of several million per second. Modification is required to MWPCs for nuclear medicine imaging. As gamma rays or X-rays cannot be detected directly, they must be converted into photo- or Compton scatter electrons. Photon-electron conversion requires the use of high atomic number materials in the body of the chamber. Pressurised xenon is the most useful form of "gas only" photon-electron convertor and has been used successfully in a gamma camera for the detection of gamma rays at energies below 100 keV. This camera has been developed specifically for high-count-rate first-pass cardiac imaging. This high-pressure xenon gas MWPC is the key to a highly competitive system which can outperform scintillator-based systems. The count rate performance is close to a million counts per second and the intrinsic spatial resolution is better than the best scintillator-based camera. The MWPC camera produces quantitative ejection fraction information of the highest quality. The detection of higher energy gamma rays has proved more problematical, needing a solid photon-electron convertor to be incorporated into the chamber. Several groups have been working on this problem with modest success so far. The only clinical detectors have been developed for positron emission tomography, where thin lead or lead-glass can provide an acceptable convertor for 511 keV photons. Two MWPC positron cameras have been evaluated clinically and one is now in routine use in clinical oncology. The problems of detection efficiency have not been solved by these detectors although reliability and large-area PET imaging have been proven.(ABSTRACT TRUNCATED AT 400 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Ott. 1993. Wire chambers revisited.. https://doi.org/10.1007/bf00169813

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The variation of intrinsic spatial resolution across the UFOV of scintillation cameras.

The aim of the present study was to investigate in detail the variation of the intrinsic spatial resolution across the useful field of view (UFOV) of gamma-cameras and to explore whether this variation could lead to observable effects in clinical images. Two gamma-cameras were used, without their collimators, to acquire 560 (99m)Tc point source images at different points across their UFOVs, in order to measure the intrinsic spatial resolution at each point. Possible clinical effects of the resolution variation were examined on images of a thyroid phantom using a LEHR collimator, acquired at different locations on the UFOV and at various distances from the collimator. The gamma-camera intrinsic resolution varied significantly across the UFOV, being generally lower at the central region and deteriorating at the edges. Pronounced local maxima and minima were found at points corresponding to the centers of the photomultiplier tubes (PMTs) and halfway in between. Maximum differences of more than 50% were observed between the points presenting the best and worst intrinsic resolution. Differences between neighboring points reached 17%. The effects of resolution variation were clearly observable on the thyroid phantom images. It was concluded that an appropriate correction algorithm might be necessary in order to correct for the variation of the intrinsic spatial resolution across the UFOV of gamma-cameras.

Gamma Cameras↗

Defining the lung outline from a gamma camera transmission attenuation map.

Segmentation of the lung outline from gamma camera transmission images of the thorax is useful in attenuation correction and quantitative image analysis. This paper describes and compares two threshold-based methods of segmentation. Simulated gamma camera transmission images of test objects were used to produce a knowledge base of the variation of threshold defining the lung outline with image resolution and chest wall thickness. Two segmentation techniques based on global (GT) and context-sensitive (CST) thresholds were developed and evaluated in simulated transmission images of realistic thoraces. The segmented lung volumes were compared to the true values used in the simulation. The mean distances between segmented and true lung surface were calculated. The techniques were also applied to three real human subject transmission images. The lung volumes were estimated and the segmentations were compared visually. The CST segmentation produced significantly superior segmentations than the GT technique in the simulated data. In human subjects, the GT technique underestimated volumes by 13% compared to the CST technique. It missed areas that clearly belonged to the lungs. In conclusion, both techniques segmented the lungs with reasonable accuracy and precision. The CST approach was superior, particularly in real human subject images.

Gamma Cameras↗

Performance comparison of two dual-head coincidence cameras of the first and latest generation.

This study compares the performance and image quality of two gamma camera based PET systems of the first and latest generation. We investigated two dual head coincidence gamma cameras (PRISM 2000XP and AXIS, manufactured in 1997 and 2001 by Picker/Philips) predominantly in accordance with the NEMA NU2-1994 and NU2-2001 protocols. All performance parameters except for spatial resolution and image quality were determined after measuring a standard cylinder over several half-life periods. Scatter and random fractions were evaluated with the sinogram technique. In order to determine spatial resolution and image quality we used phantoms as described in the NEMA NU2-2001 protocol. The efficiency of the new system was found to be increased. True count rate at activity levels used in clinical conditions is improved and scatter fraction is decreased substantially. Accordingly, improved spatial resolution and image quality were observed with the new system. Altogether, the AXIS represents a further approach to the performance of dedicated positron emission tomographs.

Gamma Cameras↗