Spatial resolution in digital mammography.

Abstract

RATIONAL AND OBJECTIVES: Digital acquisition systems currently available limit spatial resolution in digital mammography to roughly 0.1 mm/pixel. The objective of this study is to determine if high-quality mammography is possible at this resolution. METHODS: The influence of spatial resolution on diagnostic quality was investigated by comparing observer performance on film to that on digitized film. A 0.1-mm sampling distance was used for digitization. Detection of mammographic details was studied by measuring threshold contrast as a function of detail size for small circular objects in the range of 0.12 to 2.5 mm. Characterization of microcalcifications was investigated in a receiver operating characteristic (ROC) study, in which 10 radiologists read 72 mammographic details with microcalcifications, both digitally and on film. RESULTS: Digitization improved the detectability of the larger, low contrast objects, whereas for small objects the detectability did not change. The authors found that even under the most optimal circumstances, isolated spherical calcifications with diameters smaller than 0.13 mm are not detectable with film-screen mammography, despite its resolution limit of 15 line patterns per mm (lp/mm). The ability to characterize microcalcification clusters did not change significantly with digitization. However, the results suggest that differentiation of benign from malignant cases decreases slightly, and that characterization of different types of malignancies somewhat improves by digitization. Mean differences between the two modalities were considerably smaller than the interobserver variability. CONCLUSION: A relatively low spatial resolution of 0.1 mm/pixel does not prohibit high-quality diagnostic performance in digital mammography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Karssemeijer, J T Frieling, J H Hendriks. 1993. Spatial resolution in digital mammography.. https://doi.org/10.1097/00004424-199305000-00005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of 4 MV photon surface dose among Varian, Siemens, and Elekta linear accelerators for tangential breast treatment: a phantom study.

PURPOSE: We have compared the differences in a 4-MV photon surface dose among Varian, Siemens, and Elekta linear accelerators (linacs) with wedges for tangential breast treatment. MATERIALS AND METHODS: The wedge factor and the surface dose were measured using a solid water phantom and an ion chamber for each linear accelerator with various field sizes and wedge angles. A tangential treatment plan was applied to an elliptical hollow cylinder water phantom with a radiochromic film placed thereon. A dose was delivered to a simulated target in the phantom, and the resulting dose distribution was analyzed using a film scanner. RESULTS: Varian's wedges resulted in the highest wedge factors, ranging from 0.37 to 0.75 depending on the wedge angles. Varian's wedges led to the highest normalized skin doses, ranging between 0.40 and 0.73 depending on the wedge angles and field sizes. In the cylinder phantom test with two tangential beams, the Varian linac provided a nearly 20% higher maximum dose than the Siemens and Elekta linacs. CONCLUSION: The Varian linac resulted in the highest surface doses, and the Elekta linac led to the lowest for nearly all the measurement conditions we employed, including open beams.

Breast Diseases↗

[Is the application of CAD useful for radiologists for passing the official tests required for outpatient breast imaging?].

PURPOSE: To analyze whether currently available CAD systems meet the diagnostic requirements for passing screening tests (first reader CAD) and to analyze whether the additional usage of CAD systems provides significant support for the diagnosing radiologist on the basis of official screening test cases (second reading by CAD). MATERIAL AND METHODS: 200 images of 100 mammographies of 50 patients of an official screening test case collection were analyzed double-blind with and without CAD printouts (iCAD, USA ) by three radiologists: one experienced in breast analysis and CAD application, one experienced in mammography analysis but inexperienced in CAD usage, one with minimal experience with breast analysis and CAD application. All radiologists measured the largest diameter of any malignant mass. The mean value of these calculations was correlated to the largest diameter given by CAD prompts. RESULTS: The mean sensitivity and specificity increased slightly as a result of the additional usage of CAD (1 and 0.6 %, resp.). Both values are not statistically significant. The highest effect was measured for the radiologist with CAD experience, while no effect was measured for the inexperienced radiologist. CAD met the sensitivity requirements but not the specificity criteria (96 and 20.3 %, resp.). The sizes given by CAD prompts corresponded significantly with the real sizes (r = 0.45, p < 0.05). CONCLUSION: A statistically significant effect of the use of CAD could not been detected dependent on the radiological experience or the CAD experience. The effect of CAD on radiologists is still subtle despite the highly sensitive CAD performance due to the high number of false positive prompts and thus does not reach statistical significance. Sizes given by CAD prompts correlate significantly with the real sizes of malignant lesions.

Breast Diseases↗